PGx862 Wireless ceiling PIR presence/security detector Installation Instructions
©2018 Tyco Security Products, Toronto, Canada www.dsc.com Tech. Support: 1-800-387-3630
1
D-307205
PG9862/PG8862/PG4862 Overview
The PGx862 is a smart wireless ceiling PIR presence/security detector
(selected mode) that creates a 360° coverage area to detect the move-
ment of intruders in indoor areas.
The detector has the following features.
l
Presence detection mode - active 15 minutes after installation
(power-up).
l
Built-in link quality indicators eliminate the need for the installer to
physically approach the control panel and reduce installation time.
l
The device supports temperature and light level reports to com-
patible alarm systems that support temperature and light sensors.
l
Tamper protection.
l
PowerG two-way Frequency Hopping Spread Spectrum FHSS-
TDMA technology.
l
The Advanced True Motion Recognition™ algorithm (patented)dis-
tinguishes between the true motion of an intruder and any other dis-
turbances which may cause false alarms.
NOTE: For UL installations, the detector is for use with UL listed con-
trol units only.
Legend
D
A
B
C
E
Figure 1. Internal view
A
Tamper protection
B
Light sensor
C
Pyro sensor
D
Battery
E
LEDs
Inserting or replacing the battery
If the battery is already installed, pull the activation strip that protrudes
from the back of the detector.
1.
To separate the detector from the
mounting bracket, rotate the bracket
anticlockwise and pull it from the
detector.
2.
Insert the battery while observing
polarity.
3.
Align the bracket tabs with the
detector slots and rotate the detector
clockwise to verify that it is securely
attached.
Figure 2. Removing the
bracket
NOTE: It is recommended to wait about 1 minute after battery
removal before inserting the new battery.
Caution! Risk of explosion if battery is replaced by an incorrect type.
Dispose of used batteries according to the manufacturer's instructions
and according to local rules and regulations.
Enrollment
Refer to the panel installation manual for the enrollment procedure.
A general description of the procedure is provided in the following
flow chart:
Step
Procedure
1
See the installation manual for the alarm system that the
device is being enrolled on to ensure that the proper steps
are used.
2
Enter the Device Enrollment option through the specified
method and select the appropriate option to add the new
device.
3
Enroll the device by either inserting the battery to power on
the device until the enrollment is detected, or by entering the
Device ID.
4
Select the desired Zone Number.
5
Configure any device parameters that are required.
6
Mount and test the detector. See
for information
on testing the device. In addition, see the alarm systems
installation manual that the device is enrolled on for other
test procedures that are required.
NOTE: If the detector is already enrolled, you can configure the
detector parameters by programming the system, see the alarm sys-
tems installation manual for more information about device para-
meters.
NOTE: When enrolling the PGx862 detector to wireless panels
(WP80XX) with version 19.4 or lower, the detector will be enrolled as
motion detector, ID 120-xxxx, and labelled ‘Motion Sens’ in the panel.
Installation tips
Use the following as a guide for locating a suitable mounting location.
Figure 3. General Guidelines
1.
Keep away from heat sources.
2.
Do not expose to air drafts.
3.
Do not install outdoors.
4.
Avoid direct sunshine.
5.
Do not install near high voltage electrical lines.
6.
Do not install behind partitions.
7.
Mount on a solid stable surface.
WARNING! Do not partially or completely obscure the detector’s
field of view.
WARNING! To comply with FCC and ISED Canada RF exposure com-
pliance requirements, the PIR detector should be located at a distance
of at least 20 cm from all persons during normal operation. The anten-
nas used for this product must not be co- located or operated in con-
junction with any other antenna or transmitter.
NOTE: The PGx862 Wireless ceiling PIR presence/security detector
shall be installed and used within an environment that provides the pol-
lution degree max 2 and overvoltages category II in NON
HAZARDOUS LOCATIONS. The equipment is designed to be
installed only by qualified service persons.
NOTE: PGx862 shall be installed in accordance with the Standard for
Installation and Classification of Burglar and Holdup Alarm Systems,
UL 681.
Walk testing
Before permanently mounting any wireless device, temporarily mount
the device and perform a walk test. Perform a walk test of the cov-
erage area at least once a year to ensure that the detector is working
correctly.
After inserting the battery or closing the device, the detector will auto-
matically enter a stability period where the LED flashes RED for 90
seconds. Walk test the coverage area, the LED lights red each time
your motion is detected followed by 3 LED blinks. The color of the 3
LED blinks indicate the received signal strength. In walk-test mode,
regardless of the LED Selection status, the LED lights upon every
motion detection. After 15 minutes the detector automatically enters
normal mode.
The following table indicates the received signal strength.
LED Response
Signal Strength
Green LED blinks
STRONG
Orange LED blinks GOOD
Red LED blinks
POOR
No blinks
No communication
IMPORTANT! Only GOOD or STRONG signal strengths are accept-
able. If you receive a POOR signal from the device, re-locate it and
re-test until a GOOD or STRONG signal is received.
NOTE: For UL/ULC installations, only STRONG signal levels are
acceptable. After installation verify the product functionality in con-
junction with the compatible control panels HSM2HOST9, HS2LCDRF
(P)9, HS2ICNRF(P)9, PG9920, WS900- 19, and WS900- 29.
NOTE: For detailed Placement instructions refer to the control panel
reference manual.
Walk-test the coverage area by walking across the far end of the cov-
erage pattern in both directions. The red LED lights each time your
motion is detected followed by a steady LED signal strength indication.
Mounting the device
1.
Mark and drill two holes in the mounting surface. If you install
tamper protection on the detector, mark and drill one hole for the
tamper protection and one hole for one of the other available
slots.
2.
Fasten the bracket to the mounting surface with the two screws.
3.
Align the bracket tabs with the detector slots and rotate the
detector clockwise. Verify that it is securely attached.
4.
Fasten the detector to the bracket with the screw.
A
B
Figure 4. Fastening the bracket
D
E
C
Figure 5. Attaching the detector
Figure 6. Fastening the detector
A
Tamper protection
B
Bracket screw slots
C
Isolation strip
D
Bracket tabs
E
Detector slots
The following table outlines the detection distance in relation to the
mounting height.
Height
2 m
3 m
4 m
Detection distance 3.1 m 3.75 m 5 m
LED Operation
LED Indications
Event
Red LED blinks
Stabilization (warm- up 90 seconds)
Red LED on 0.2 seconds Tamper open/close
Red LED on 2 seconds
Intruder alarm
Temperature and light display
For instructions on displaying the temperature of zones on the correct
panel as measured by the PGx862, refer to the panel installation guide.
Specifications
GENERAL
Detector Type
One pyroelectric sensor operating in a dual separated configuration
OPTICAL
Lens Data
Fresnel type lens.
Number of beams: 72
Max. coverage
Ø10 m/360° at the maximum installation height of 4 m
ELECTRICAL
Power Supply: Type C
Internal Battery
3V Lithium battery, type CR-123A. For UL installations, use
Panasonic and GP only
Nominal Battery Capacity: 1450 mAh
Battery Life (typical use)
Minimum 1 year. For typical use (security mode), 5 years (not veri-
fied by UL).
Low Battery Threshold: 2.4 V
NOTE: Inability to connect with wireless network, or wireless link
quality no higher than 20% may significantly reduce the expected bat-
tery life.
Battery Power Test
Performed immediately upon battery insertion and periodically after
every several hours.
The power supply is type C in accordance with EN 50131-6 Docu-
mentation – Clause 6.
Current Consumption
20 μA average quiescent , maximum 150 mA (during transmission)
Figure 7. Beam distribution at 2.7 m
Figure 8. Beam distribution at 4 m
FUNCTIONAL
Alarm Period: 2 seconds
WIRELESS
Frequency
Europe and rest of world: 433- 434 MHz, 868- 869 MHz USA: 912- 919