TransCore 05531 User Manual
Commands
7-25
TF
RF timeout infinite, never expires (factory default)
I0
input inversion disabled (factory default)
I1
input inversion enabled
For example, if factory default settings are assigned, the reader message is
PRST P0 D0 A2 TF I0
which means that presence without tag reports is disabled, minimum presence true
period is 0, RF off control on timeout or presence false, infinite RF timeout, and input
inversion disabled.
period is 0, RF off control on timeout or presence false, infinite RF timeout, and input
inversion disabled.
530 Display RF0 Filter Status*
Command #530 displays the parameter set for the RF channel input, including the
selected unique ID code criteria (#410N Select Unique ID Code Criteria) and the valid
ID code criteria, which are fixed at one acquisition.
selected unique ID code criteria (#410N Select Unique ID Code Criteria) and the valid
ID code criteria, which are fixed at one acquisition.
Reader response:
RF0S U<0 to 2> V0
where
U0
One ID separation (factory default)
U1
Two ID separations
U2
Transmit all IDs
V0
Valid ID code criteria of one acquisition (fixed)
For example, if factory default settings are assigned, the reader message is
RF0S U0 V0
which means separation of one ID for uniqueness filtering and a valid ID code criteria
of one acquisition.
of one acquisition.
532 Display Wiegand Mode Status
Command #532 displays the Wiegand mode status as either enabled or disabled.
Reader response:
TOF <0 to 1>
where
0
Wiegand mode disabled
1
Wiegand mode enabled