Commands
7-43
Command #6920 turns off RF power based on the timeout established by command 
#693N
 Select RF Timeout Period.
Command #6921 allows RF power to be turned off either after the timeout period or 
upon acquisition of a valid tag ID, whichever occurs first.
Command #6922 turns off RF power either after the timeout period or upon the pres-
ence false condition, whichever occurs first.
Reader response:
Done
693N   Select RF Timeout Period
Command #693N selects the RF timeout period used by command #692N Select RF 
Control Algorithm. Values for N range from 0 through F.
Command #693F disables the RF timeout. The reader turns off the RF immediately 
following the acquisition of a valid tag, whether or not it is unique. This control algo-
rithm may be used in Wiegand mode to ensure that the tag data is transmitted once and 
only once per presence on both serial and Wiegand ports.
Note:  The dual-protocol Encompass 4/4800 Multiprotocol Reader internal timing 
varies depending on the operative tag read mode and the type of tag in the read field. 
Values listed in the middle column of Table 7-19 as
sume an ID operational tag read 
mode (64-bit ID data from eGo tags, ignore ATA tags) and an eGo tag in the read 
field. Values in the right column of Table 7-19 a
ssume an ATA operational tag read 
mode (reads ATA data from ATA tags) and an ATA tag in the read field. Actual pulse 
length output of the reader may vary from the specified value.
Uppercase or lowercase characters are allowed for N; for example, hex digits A 
through F or a through f. The commands and corresponding timeouts are shown in 
Table 7-19  Timeout Period Values
Command
Approximate timeout (ms) for 
ID, IATA, Dual 1, and Dual 2 
tag read mode operation
Approximate timeout (ms) for 
ATA tag read mode operation
6930
0 (always expired)
0 (always expired)
6931 to 6937
48 ms
150 ms
6938
60 ms
175 ms
6939
92 ms
200 ms
693A
152 ms
370 ms
693B
300 ms
680 ms
693C
452 ms
1000 ms