Commands
7-45
characters to be entered. When setting the serial number, skip the fourth (middle) 
character of the seven-character number shown on the reader product label.
Note:  Once assigned, the serial number is preserved during power-down and the 
loading of default parameters.
Reader response:
Done
696S...S   Store Hardware Configuration String
Command #696S...S stores hardware configuration information into reader mem-
ory.
The hardware configuration string is assigned according to the following format:
696S...S
where S...S is the hardware configuration string that may contain as many as 20 
uppercase or lowercase ASCII alphanumeric characters.
Note:  Once assigned, configuration information is preserved during power-down and 
the loading of default parameters.
Reader response:
Done
Auxiliary Reader Control — Command Group 8
Group 8 commands provide control of reader functions, such as the sense input lines.
82N   Select Input Status Change Report Option
Command #82N selects the input lines to be monitored to report any change in input 
status. The enabled input lines are monitored for any changes in the logic states. If a 
change is detected, the reader generates an input status change message and treats it as 
a tag ID. If the auxiliary information option is enabled, the input status field displays 
the current input values. The value for N specifies the report options as shown in 
Table 7-21.
Table 7-21  Input Status Change Report Options
Command
Report Option
820
Disable status change reports (factory default)
821
Report change on input0
822
Report change on input1
823
Report changes on input0 and input1