Codan Radio Communications VT-3-150-SN User Manual

Page of 262
3-6
VHF Amplifier Instruction Manual VT-3 132 - 174 MHz
3.6.2.5
Antenna VSWR Overload
1.
Disconnect the radio communications test set and so  that the  amplifier  is  terminated
with an open circuit.
2.
Monitor the current from the +9.5 Vdc supply.
3.
Adjust R37, the VSWR  overload adjustment, clockwise until a noticeable drop in the
+9.5 Vdc current occurs.
4.
Reconnect the radio communications test set and, the +9.5 Vdc current should return
to the previous level.
3.6.2.6
Procedure Verification
1.
Verify that the current drawn from the +13.8 Vdc supply is less than 1.5 A and from
the +9.5 Vdc supply is less than 1.2  A  when transmitting  full  RF  output  power (8
Watts).
2.
Turn off the power to the transmitter.