Codan Radio Communications VT-3-150-SN User Manual

Page of 262
3-4
VHF Amplifier Instruction Manual VT-3 132 - 174 MHz
4.
Monitor the +9.5 Vdc and 13.8 Vdc supply current and adjust R7, the output power
adjustment, so that approximately 1 Amp is being drawn on the +9.5 Vdc line and 1.3
Amps  or  less  is  being  drawn  on  the  13.8  Vdc  line.    This  should  produce
approximately 8 Watts.
5.
If only a 6 or 7 watt output is obtained, adjust the low pass  filter coil pairs L2/L3 and
L1/L4 to obtain 8 watts.
3.6.2.2
Output Power Alarm (Forward Power)
Open Collector Output
    * note:  the output power alarm output is factory configured as an open collector output
so  a pull-up  resistor  may  be  required on  transmitter  pin  B26  if  one  is  not  already
present.
1.
Adjust  R7,  the  output  power adjustment,  to  the  output  power at  which  the  Output
Power Alarm is to be activated.
2.
Monitor transmitter pin B26, the Output Power Alarm line, and slowly turn R21, the
output power alarm adjustment, clockwise until pin B26 goes low.  The alarm is now
set for the current output power of the transmitter.
Linear Output
1.
Open  the  amplifier  case  to  disable  (open  circuit)  jumper  JU2  and  enable  (short)
jumper JU1.
2.
Monitor transmitter pin B26 with a voltmeter.
3.
Adjust R7, the output power adjustment, for full transmitter output power.
4.
Adjust R21, the output power alarm adjustment, so  that the  voltmeter  indicates  +7.5
Vdc for full transmitter output power.
5.
Turn R7, the output power adjustment, fully counterclockwise.  The voltmeter should
read approximately +3 Vdc.
6.
Disconnect the voltmeter.