Codan Radio Communications VT-3-150-SN User Manual

Page of 262
VHF Amplifier Instruction Manual VT-3 132 - 174 MHz
3-5
3.6.2.3
Output Power
1.
Turn  R7,  the  output  power adjustment,  clockwise  to  the  desired  transmitter  output
power.
3.6.2.4
Antenna VSWR Alarm (Reverse Power)
Open Collector Output
    * note:  the  antenna  VSWR  alarm  output  is  factory  configured  as  an  open  collector
output  so  a  pull-up  resistor  may  be  required on  transmitter  pin  Z26  if  one  is  not
already present.  The output power alarm must be set first before the antenna VSWR
alarm can be set.
1.
Disconnect the radio communications test and terminate  the  transmitter  with  the  3:1
mismatch load.
2.
Monitor  pin  Z26,  the  Antenna  VSWR  Alarm  line,  and  turn  R36  fully
counterclockwise.  Pin Z26 should be high.  Slowly turn R36 clockwise until pin Z26
is pulled low.  Put the 50  ohm  load  back  on  again,  Pin  Z26  should  go  high.    The
reverse power trip point is now set for a VSWR of 3:1.
Linear Output
1.
Open  the  amplifier  case  to  disable  (open  circuit)  jumper  JU3  and  enable  (short)
jumper JU4.
2.
Monitor transmitter pin Z26 with a voltmeter.
3.
Disconnect the radio communications test  set  and  terminate  the  transmitter  with  the
3:1 mismatch load.
4.
Adjust R36, the VSWR alarm adjustment, so that the voltmeter indicates +5 Vdc for a
3:1 mismatch.
5.
Put the 50 ohm load back on again.  The voltmeter should read approximately 0 Vdc.
6.
Disconnect the voltmeter.