Multi-battery charger
Follow the steps shown below to charge:
(1) Connect a dedicated AC cable to the multi-battery charger.
(2) Connect the AC cable to the AC adapter.
(3) Put the AC cable plug into the inlet.
(4) Mount the battery pack on the battery charger so that the electrodes of the battery pack can be
aligned with the metallic terminals of the battery charger.
(5) The CHARGE lamp on the battery charger lights red to start charging.
(6) The CHARGE lamp changes to green when the battery is fully charged.
(7) Remove the battery pack after charging is completed.
(8) Unplug the AC cable from the inlet.
CHARGE lamp (Recharge state indication)
Battery state
CHARGE lamp
Not connected
Off
During charging
Red on
Charge completion
Green on
Error Red
blinks
Hints
• If the CHARGE lamp does not light for a few minutes after start of charging, the battery
pack is out of order.
Stop using the battery pack.
• If an error is detected in the battery pack, the CHARGE lamp blinks.
The error may be caused by going out of the battery life, so replace the battery pack
with a new’s.
• The battery pack and the battery charger may be heated to a very slight extent during
charging. There is no problem.
WARNING
♦ The AC adapter for the multi-battery charger differs from the one of the printer.
DO NOT use the dedicated AC adapter for other devices. Doing so may cause a fire
or an accident by an explotion, an ignition, or a generating heat.