Facilities Connector
The Facilities connector is a 15-way D-type filtered socket used for connecting to associated parts of a
system. The connector pin-out is shown below and detailed in Table 24.
Table 24  Facilities Connector
Pin Number
Signal
Characteristic
1
Ground
0 V.
2
E-BIT (input)
An external BIT input that connects from any ancillary equipment having 
a compatible BIT alarm output.
When this input is active, the transmitter’s front panel Alarm indicator 
flashes and an E-BIT message is displayed on the LCD. The input is 
TTL having a 4.7 kohm pull-up resistor to 5 V. The input is configurable 
from the front panel to be active high or low.
3
PTT output
Grounding solid state relay. +60 to -60 V, ac or dc, 100 mA maximum, 
configurable normally open or normally closed. Activated 35 ms (±1 ms) 
before the start of the power ramp up to allow for the antenna relay pull-
in time.
4
External VSWR input
Used to indicate an external VSWR fault. TTL input with 4.7 kohm pull-
up to 5 V. Configurable active high or low.
5
6
Antenna change-over 
(output)
Antenna change-over 
common (output)
Solid state relay linked to pin 6. See 
 for further detail.
Solid state relay linked to pin 5.
7
Not used
-
8
Ground
0 V.
9
Output supply
This output is between 21.6 and 32 Vdc (nominally 28 V) fused at 
500 mA.
10
Inhibit (input)
Active signal prevents the transmitter keying. TTL with 4.7 kohm pull-up 
to 5 V. Configurable active high or low.
11
BIT interruptive test 
(input)
Active signal initiates a BIT test. TTL with 4.7 kohm pull-up to 5 V. 
Configurable active high or low. Must be asserted for >300 ms.
12
Not used
-
13
Ready (output)
An output that is active when the radio is ready to transmit and no faults 
are detected. Open collector NPN transistor grounding output, 200 mA 
maximum, configurable normally open or normally closed.
14
Tape (output)
An audio output for connection to a recording system. 0 dBm fixed 
output into 600 ohm for 90% modulation depth.
15
Reserved (output)
Do not connect to pin 15 unless advised to do so by Park Air.
1
8
9
15
Pin-out of Facilities connector looking into the mating face of
the chassis mounted socket.
A suitable free plug is detailed in 