XT30/XT50 Installation Guide 
Digital Monitoring Products
11
InstallatIon
Powered Zone for 2-Wire Smoke Detectors
11.1  Terminals 25 and 26
A resettable 2-wire Class B powered zone is provided on terminals 25 (positive) and 26 (negative) of the
panel. For programming purposes, the zone number is 10 on the XT30/XT50. The zone uses a Model 309,
3.3k Ohm EOL resistor (provided with the panel) and has an operating range of 8.8 to 13.9 VDC.
The compatibility identifier is: A.
Caution: Sensor reset on zone 10 will drop power to devices on this zone, causing the panel to sense an
open condition on all zone types other than Fire, Fire Verify, and Supervisory. Whenever non-Fire and non-
Supervisory zone types are used on zone 10, make the appropriate adjustments to the zone’s Armed Action
to prevent false alarms from occurring.
Manufacturer
Model
Detector 
ID
Base
Base 
ID
# of 
Detectors
Zone 
Expansion 
Modules
Detection Systems
DS250, DS250TH
B
MB2W, MB2WL
A
10
715, 715-8, 
715-16, 725
Detection Systems
DS250HD
B
MB2W, MB2WL
A
10
715, 715-8, 
715-16
Detection Systems
DS282, DS282TH
B
10
715, 715-8, 
715-16, 725
DMP/Hochiki
SLK-835
HD-5
HSB-200, 
HSB-200N
HB-55
7
715, 715-8, 
715-16
DMP/Hochiki
SLR-835
HD-3
NS6-100
HB-55
7
715, 715-8, 
715-16, 725
DMP/Hochiki
SLR-835B
HD-6
7
715, 715-8, 
715-16, 725
Sentrol/ESL
429AT, 521B, 521BXT
S09A
12
715, 715-8, 
715-16