XT30/XT50 Installation Guide
12
InstallatIon
Annunciator Outputs
12.1  Description
The four annunciator outputs can be programmed to indicate the activity of the panel’s zones or conditions
occurring on the system.  Annunciator outputs do not provide a voltage but instead switch-to-ground voltage 
from another source.  The outputs can respond to any of the conditions listed below:
1)  Activation by zone condition: Steady, Pulse, Momentary, or Follower
6)  Ambush alarm
2)  Manually from the keypad
7)  Exit and Entry timers
3)  Communication failure
8)  System Ready
4)  Armed area annunciation
9)  Late to Close
5)  Fire Alarm or Fire Trouble
 
12.2  Harness Wiring
The open collector outputs are accessible by installing the DMP 300 Harness on the 4-pin header labeled J11.
The output locations are shown below.  
 
Output   Color    Wire 
Output   Color    Wire
1
Red
1
3
Green  3
2
Yellow
2
4
Black
4
12.3  Model 860 Relay Module
Connect a Model 860 Relay Module to the panel to provide relays for the annunciator outputs that can be
used for electrical isolation between the alarm panel and other systems or for switching voltage to control 
various functions. The module includes one relay and provides three additional sockets for expansion of up
to four relays. Power is supplied to the relay coils from the panel keypad bus. The 860 mounts inside the
panel enclosure using the 3-hole mounting configuration. Plastic standoffs are provided with the module for
ease of installation. A 4-wire harness is also provided that connects the Model 860 to the panel.
Relay Contact Rating:  1 Amp at 30 VDC