22
ZONE INFORMATION
15.5 
Area Assignment
All non-24-hour zones are automatically assigned to Area 1.
15.6 
Arming Zone Assignment
All Arming zones are automatically assigned to Area 1.
15.7 
Style
This option specifies the style for the arming/disarming operation. The default for
STYLE: is TGL (toggle). Pressing any Select key displays the STYLE options. To view more
style options press the command key. The following is a description of the action for
each option condition.
TGL (Toggle) - When the zone changes from normal to shorted, the programmed areas
toggle between the armed or disarmed condition. When restored to normal, no action
occurs. When the zone is opened from a normal (disarmed) state, a trouble is reported.
When opened from a shorted (armed) state, an alarm is reported and the zone is
disabled until you disarm the area(s) from either a keypad or Remote Link™ computer.
ARM - When the zone is shorted, the programmed area is armed. When restored to
normal, no action occurs. When the zone is opened from a normal (disarmed) state, a
trouble is reported. When opened from a shorted (armed) state, an alarm is reported.
DIS (Disarm) - A short will disarm the area. When restored to normal, no action occurs.
When the zone is opened from a normal (disarmed) state, a trouble is reported.
STEP - A short will arm the area and beep the keypad once. A normal condition will cause
no action. An open condition will disarm the programmed area and beep the keypad for
one second.
Note: When using an arming/disarming keyswitch, locate the keyswitch within the
protected area.
MNT (Maintain) - When the zone is shorted, the programmed area is armed. When
restored to normal, the programmed area is disarmed and any alarm bells are silenced. 
When the zone is opened from a normal (disarmed) state, a trouble is reported. If
opened from a shorted (armed) state, an alarm is reported and the zone is disabled until 
you disarm the area from either a keypad or Remote Link™ computer.
15.8 
Next Zone
When YES is selected, the programming for the zone terminates and the display returns
to ZONE NO: - allowing you to enter a new zone number. Select NO to make changes to
the Alarm Action for a zone.
15.9 
Alarm Action
The Alarm Action section allows you to change or confirm the default alarm
characteristics of a zone type.
If you selected the non-24-hour zone type Blank, Night, Day, Exit, Auxiliary 1, or
Auxiliary 2, the Alarm Action programing begins with Disarmed Open.
If you selected the 24-hour zone type Panic, Emergency, or Supervisory, the Alarm Action
programming begins with Armed Open.
15.10 
Disarmed Open
Defines the action taken by the communicator when the zone is opened while the area is 
disarmed. There are three actions to define:
•  Message to Transmit
•  Output/Favorite Number
•  Output Action
You must also make these selections for the Disarmed Short, Armed Open, and Armed
Short zone conditions. Press the COMMAND key to continue.
15.11 
Message To Transmit
You can send two report types to the receiver: Alarm and Trouble. These are represented
by the characters A and T. Press any Select key to display the zone report options.
ALARM - Selecting A allows an alarm report to be sent to the receiver. See the Bell Action
section. The zone name appears in the communicator’s alarmed zones status lists.
TROUBLE - Selecting T allows a trouble report to be sent to the receiver and the zone
name to appear in the communicator’s alarmed zones status lists.
LOCAL - When you select L, an alarm report is NOT sent to the receiver. The bell output
still activates according to zone type and the zone name appears in the communicator’s
alarmed zones status lists.
– (dash) - When you select – , reports are NOT sent to the receiver. The bell output does
not activate and there is no display in the communicator’s alarmed zones status list.
Only the programmed Output Number activates.
15.12 
Output Number
AREA NO: -
AREA: 
STYLE:  
TGL
TGL  ARM DIS STEP
MNT
NEXT ZN? 
  NO  YES
ALARM ACTION . . .
DISARMED OPEN
MSG: ALARM
A  T L -
OUTPUT NO:    
0