Digital Monitoring Products Inc PC0181 User Manual

Page of 58
XTLplus Installation and Programming Guide 
Digital Monitoring Products
33
ZONE INFORMATION
keypad three times. A normal condition will cause no action. An open condition will 
disarm the programmed areas and beep the keypads for one second.
Note: This arming style is designed for wireless arming pendants. When using a 
arming/disarming keyswitch, locate the keyswitch within the protected area.
MNT (Maintain) - When the zone is shorted, the programmed areas are armed. 
When restored to normal, the programmed areas are disarmed and any alarm bells 
are silenced. When the zone is opened from a normal (disarmed) state, a trouble 
is reported. If opened from a shorted (armed) state, an alarm is reported and the 
zone is disabled until you disarm the area(s) from either a keypad or Remote  
Link™ computer.
33.8      DMP Wireless
For wireless key fob programming see the 1144 Series Key Fob section.
Note: All wireless programming is stored in the XTLplus panel. Each time the panel powers up, when the 
programmer STOP routine is selected or the panel is reset, the wireless receiver memory refresh could 
take up to 45 seconds to complete depending on the number of wireless zones programmed and the 
Red LED remains on during this time. Normal wireless receiver operation is inhibited during the memory 
refresh period.
33.8.1 
Serial Number Entry
Enter the eight digit serial number, including leading zeros, found on the  
wireless device.
33.8.2 Contact
This option displays if the serial number entered is for an 1101, 1103, or 1106 
Universal Transmitter or 1114 Wireless Four-Zone Expander. Press any top row key 
to select the contact.
This option displays when programming an 1101, 1103, or 1106 Universal 
Transmitter. Select INT to use the internal reed switch contacts. Select EXT to 
connect an external device to the 1101, 1103, or 1106 terminal block. Default is 
INTERNAL.
By allowing both of the transmitter contacts (INT and EXT) to be used at the same 
time, two zones may be programmed from one transmitter. When using multiple 
contacts, you must use consecutive zone numbers.
For example, program transmitter serial number 01345678 as Zone 11 with an INT 
contact type and Zone 12 with an EXT contact type. The same serial number is 
used for both zones.
This option displays when programming an 1114 zone expander which provides four 
input contacts. Press any top row key to select the contact. Default is Contact 1. 
Select the contact number to program. The same transmitter serial number is used 
for all four contacts. When using the contacts, you must use consecutive zone 
numbers.
For example, use serial number 08345678 to program Contact 1 for Zone 21, 
Contact 2 for Zone 22, Contact 3 for zone 23, and Contact 4 for zone 24.
A tamper on the 1114 is transmitted as the zone number assigned to Contact 1.
This message displays when the Contact is already programmed for another zone. 
The programmed zone number displays.
The Normally Open option only displays when EXT is selected as the Contact type. 
For external devices connected to the 1101 terminal block, select NO to use 
normally closed (N/C) contacts. Select YES to use normally open (N/O) contacts. 
Default is NO.
33.8.3 
Supervision Time
Press any top row key to select the supervision time required for the wireless zone. 
Press COMMAND to accept the default time. Default is 240 minutes.
Select the required number of minutes. The transmitter must check in at least 
once during this time or a missing condition is indicated for that zone. 1100 Series 
transmitters automatically checkin based on the supervision time selected for the 
wireless zone, no additional programming is needed. If two zones share the same 
transmitter, the last programmed supervision time is stored as the supervision time 
for both zones. Zero (0) indicates an unsupervised transmitter.
The 3 minute supervision time is only available for zone types of Fire (FI), Fire 
Verify (FV), and Supervisory (SV).
Note: When the panel is reset the supervision timer restarts for all wireless zones.
33.8.4 
LED Operation
This only displays when programming a panic or pendant transmitter. Select YES to 
MNT
SERIAL #: -
INT EXT
CONTACT: x
 1 
ALREADY USED
Zxx
NORM OPEN NO YES
SUPRVSN TIME:
XX
0  3 60 240
LED OPER  NO  YES