ZONE INFORMATION
Press the select key under the key fob button to program. The following list 
identifies the default button assignments:
TOP  Arming with areas 1, 2, and 3 assigned
BTM  Disarming with areas 1, 2, and 3 assigned
LFT  Panic Alarm (PN) with no output assigned
RGT  Arming with Area 1 assigned
33.9.6 
Key Fob Button Selection (Two Buttons)
This option only displays if the key fob being programmed is a two-button model. 
Press the select key under the key fob button to program. The following list 
identifies the default button assignments:
TOP  Arming with areas 1, 2, and 3 assigned
BTM  Disarming with areas 1, 2, and 3 assigned
33.9.7 
Button Action
This option specifies the Button Action for an individual key fob button. The 
default action for the button selected is displayed. Press any select key to display 
the Button Action options. To view more options press the COMMAND key.
ARM (Arm) - Arms selected areas and force arms bad zones.
DIS (Disarm) - Disarms selected areas.
TGL (Toggle Arm) - Toggles arm/disarm for selected areas and force arms bad 
zones when arming.
STA (Status) - Causes the key fob LED to indicate the arm/disarm status of the 
system.
PN (Panic) - Triggers a Panic zone type alarm with no restoral.
PN2 (Panic 2) - Triggers a Panic zone type alarm with no restoral when pressed 
simultaneously with any other Panic 2 button. No action occurs when pressed 
alone.
EM (Emerg) - Triggers an Emergency zone type alarm with no restoral.
EM2 (Emerg 2) - Triggers an Emergency zone type alarm with no restoral when 
pressed simultaneously with any other Emergency 2 button. No action occurs when 
pressed alone.
OUT (Output) - Causes an output to turn on steady, pulse, momentary,  
toggle or off.
RST (Sensor Reset) - Causes the panel to perform a standard Sensor Reset.
UN (Unused) - The button is not used and performs no action.
33.9.8 
Button Press Time
This option specifies the amount of time (SHORT or LONG) the user must press the 
button before the key fob sends a message to the wireless receiver. The default 
press time displays. Press any select key to set the Button Press Time for Arm, 
Disarm, Toggle, Status, Output, and Sensor Reset.
Note: The Button Press Time is not programmable on Panic (PN or PN2), Emergency 
(EM or EM2) or Unused (UN) zones. For those zones the button press time is always 
two (2) seconds.
SHORT - Press the button for one-half (1/2) second to send the message to the 
wireless receiver.
LONG - Press the button for two (2) seconds to send the message to the  
wireless receiver.
33.9.9 
Arm/Disarm Area Selection
For Area systems, enter the areas 1 to 6, to be armed/disarmed by the Key Fob 
button being programmed.
This specifies the area to be armed by the Key Fob button being programmed. 
For All/Perimeter systems, choose PERIM or ALL. 
For Home/Sleep/Away or Home/Away systems, choose HOME, SLEEP, or AWAY.
After selecting the areas, for one-button key fobs the Zone No.: option displays. 
For two-button or four-button key fobs, the Key Fob Button Selection option 
displays to program additional buttons. 
 
 
 
 
33.9.10 
Output Number
You can specify a wireless output to operate when OUT (Output), PN (Panic), PN2 
TOP  BTM
ACTION: XXXXXXX
ARM  DIS  TGL  STA
 PN  PN2   EM  EM2
OUT  RST  UN
PRESS TIME:  XXXXX
SHORT
 LONG
AREA: 1 2 3 4 5 6
ARM AREAS:    PERIM
OUTPUT NO: 0