35
ZONE INFORMATION
Press the select key under the key fob button to program. The following list
identifies the default button assignments:
TOP Arming with areas 1, 2, and 3 assigned
BTM Disarming with areas 1, 2, and 3 assigned
LFT Panic Alarm (PN) with no output assigned
RGT Arming with Area 1 assigned
33.9.6
Key Fob Button Selection (Two Buttons)
This option only displays if the key fob being programmed is a two-button model.
Press the select key under the key fob button to program. The following list
identifies the default button assignments:
TOP Arming with areas 1, 2, and 3 assigned
BTM Disarming with areas 1, 2, and 3 assigned
33.9.7
Button Action
This option specifies the Button Action for an individual key fob button. The
default action for the button selected is displayed. Press any select key to display
the Button Action options. To view more options press the COMMAND key.
ARM (Arm) - Arms selected areas and force arms bad zones.
DIS (Disarm) - Disarms selected areas.
TGL (Toggle Arm) - Toggles arm/disarm for selected areas and force arms bad
zones when arming.
STA (Status) - Causes the key fob LED to indicate the arm/disarm status of the
system.
PN (Panic) - Triggers a Panic zone type alarm with no restoral.
PN2 (Panic 2) - Triggers a Panic zone type alarm with no restoral when pressed
simultaneously with any other Panic 2 button. No action occurs when pressed
alone.
EM (Emerg) - Triggers an Emergency zone type alarm with no restoral.
EM2 (Emerg 2) - Triggers an Emergency zone type alarm with no restoral when
pressed simultaneously with any other Emergency 2 button. No action occurs when
pressed alone.
OUT (Output) - Causes an output to turn on steady, pulse, momentary,
toggle or off.
RST (Sensor Reset) - Causes the panel to perform a standard Sensor Reset.
UN (Unused) - The button is not used and performs no action.
33.9.8
Button Press Time
This option specifies the amount of time (SHORT or LONG) the user must press the
button before the key fob sends a message to the wireless receiver. The default
press time displays. Press any select key to set the Button Press Time for Arm,
Disarm, Toggle, Status, Output, and Sensor Reset.
Note: The Button Press Time is not programmable on Panic (PN or PN2), Emergency
(EM or EM2) or Unused (UN) zones. For those zones the button press time is always
two (2) seconds.
SHORT - Press the button for one-half (1/2) second to send the message to the
wireless receiver.
LONG - Press the button for two (2) seconds to send the message to the
wireless receiver.
33.9.9
Arm/Disarm Area Selection
For Area systems, enter the areas 1 to 6, to be armed/disarmed by the Key Fob
button being programmed.
This specifies the area to be armed by the Key Fob button being programmed.
For All/Perimeter systems, choose PERIM or ALL.
For Home/Sleep/Away or Home/Away systems, choose HOME, SLEEP, or AWAY.
After selecting the areas, for one-button key fobs the Zone No.: option displays.
For two-button or four-button key fobs, the Key Fob Button Selection option
displays to program additional buttons.
33.9.10
Output Number
You can specify a wireless output to operate when OUT (Output), PN (Panic), PN2
TOP BTM
ACTION: XXXXXXX
ARM DIS TGL STA
PN PN2 EM EM2
OUT RST UN
PRESS TIME: XXXXX
SHORT
LONG
AREA: 1 2 3 4 5 6
ARM AREAS: PERIM
OUTPUT NO: 0