XTLplus Installation and Programming Guide
42
APPENDIX
Activate Cell
Note:
 If the 265C Cellular Communicator has not been previously activated, Automatic Cellular Activation 
is performed when the panel powers up or is reset. 
Activate Cell (discussed below) is only necessary when 
Automatic Cellular Activation is not successful and communication was not established.
To begin the cellular activation for a 265C CDMA Cellular Communicator, verify that the 265C MEID has been 
added for the panel using Remote Link or by calling Customer Service (1-800-641-4282). At the keypad, press 
any select key when 
ACTIVATE CELL is displayed on the keypad. When the SURE NO YES? confirmation menu 
appears press the select key beneath YES to complete the cellular activation.
Successful Display
Failure Display
CELL ACTIVATED
NOT ACTIVATED
Wi-Fi Signal Strength (Wi-Fi SIGNAL)
This option tests the signal strength of the selected SSID. Press any select key to 
display Wi-Fi signal strength. The
’s represent the signal strength 0-7.
Wi-Fi Signal Strength
Number of Bars
Indication
7
Good Signal (Excellent for consistent operation)
6
5
4
Average Signal (Expect consistent operation)
3
2
1
Weak Signal (Will not operate reliably. Relocate Wi-Fi 
equipment or add a Wi-Fi extender for better reception.)
0
No Signal
Z-Wave Test Option
This feature allows the installer to test XTLplus communication with Z-Wave 
devices. A successful test indicates a response from a device. Press any select key 
to view the Z-Wave Device List.
Press COMMAND to advance through each Z-Wave device and press any select key 
to begin the test on the device displayed.
The name of the device displays above the device number. The current number of 
successful communications followed by the total number of attempts displays to 
the right of the device number. The test stops after 99 attempts.
Press COMMAND to view the final number of successful communications.
Exiting the Diagnostics program
Press the COMMAND key until 
STOP displays. Press any select key. The keypad returns to the Status  
List display.
36.5  Using the Walk Test
The XTLplus panel provides a walk test feature that allows a single technician to test all the protection 
devices connected to zones on the system. Conduct the Walk Test within 30 minutes of resetting the panel. 
The Walk Test automatically ends if no zones are tripped for 20 minutes. 
TEST IN PROGRESS displays at all 
keypads. When five minutes remain, 
TEST END WARNING displays. If any areas are armed the Walk Test does 
not start and 
SYSTEM ARMED displays.
 
Walk Test
To conduct the Walk Test, reset the control panel by pressing the RESET button 
then wait one minute. From the keypad, enter the code 8144. The keypad displays 
WALK TEST.
WLS (Wireless Check-in Test) - Select WLS to automatically test 1100 Series 
wireless transmitter communications. Includes all wireless devices except key fobs 
and transmitters programmed for a supervision time of 0 (zero).
PIR (Wireless PIR Walk Test) - The PIR Walk Test allows the installer to verify the 
1126 and 1127 operation. When enabled, the 1126 LED flashes each time motion is 
detected for up to 30 minutes. This is a local test only and no messages are sent to 
the Central Station.
 
SIGNAL
▐▐▐▐▐▐▐ 
HOMENET123
TEST ZWAVE
DEVICE LIST:
HALLWAY LIGHT
HALLWAY LIGHT
LIGHT 02 0/0
HALLWAY LIGHT
99/99 SUCCESSFUL
WALK TEST
STD WLS PIR