False Alarm Reduction Programmable Options 
ANSI/SIA CP-01-2010
41.1  Shipping Defaults and Recommended Programming
SIA CP-01 FEATURE 
PARAGRAPH # AND 
DESCRIPTION
DMP PROGRAMMING 
GUIDE LT-1434 
SECTION #
REQUIREMENT
RANGE
SHIPPING 
DEFAULT
RECOMMENDED 
PROGRAMMING*
4.2.2.1 Exit Time
28.6 Exit Delay
Required 
(Programmable)
45 sec. - 250 sec.
60 
Seconds
60 Seconds
4.2.2.2 Progress 
Annunciation
33.14 Prewarn 
Address
Allowed
Individual keypads may 
be disabled per zone
All 
keypads 
enabled
All keypads enabled
4.2.2.3 Exit Time Restart 28.6 Exit Delay
Required Option
For re-entry during exit 
time
Enabled
Enabled
4.2.2.5 Auto Stay Arm on 
Unvacated Premises
28.17 Occupied 
Premise - See Install 
Guide
Required Option 
(except for remote 
arming)
Occupied Premise NO/
YES option
Enabled
Enabled Yes 
for Residential 
Applications
4.2.4.4 Exit Time and 
Progress Annunciation/
Disable - for Remote Arm
Not Available on 
Remote Arming
Allowed Option
Progress Annunciation 
Always disabled for 
Remote Arming
Not 
Available
Remote Arming not 
allowed for CP-01 
installations.
4.2.3.1 Entry Delay(s)
28.5 Entry Delay
Required 
(Programmable) Only 
use Entry Delay 1. Do 
not use Entry Delay 2.
30 sec. – 240 Sec. 
**
30 
Seconds
At least 30 
Seconds 
**
4.2.5.1 Abort Window – 
for Non-Fire Zones
36.2 Transmit Delay
Required Option
Disable by zone or zone 
type
Enabled 
NT DY EX 
Zone
Enabled
4.2.5.1 Abort Window 
Time – for Non-Fire 
Zones
36.2 Transmit Delay
Required 
(Programmable)
20 sec., 30 sec., or 
40 sec. 
**
30 
Seconds
At least 20 
Seconds 
**
4.2.5.1.2 Abort 
Annunciation
36.2 Transmit Delay
Required Option
Annunciate that no 
alarm was transmitted  Yes
Yes
4.2.5.4.1 Cancel 
Annunciation
Always Enabled - Not 
Programmable
Required Option
Annunciate that a 
Cancel was transmitted 
(S49)
Always 
Enabled
Yes
4.2.6.1 & 4.2.6.2 Duress 
Feature
User Code + 1 = 
Ambush Code Not 
Available
Allowed Option
No 1 + derivative of 
another user code/no 
duplicates with other 
user codes
Code +1 
Always 
Disabled
Not Programmable
4.3.1 Cross Zoning
33.16 Cross Zone
Required Option
Yes/No Zone 
Programming
No
Enabled using 
two or more 
programmed zones
4.3.1 Programmable 
Cross Zoning Time
28.7 Cross Zone Time Allowed
4 sec. - 250 sec.
0 Seconds Per walk path in 
protected premises
4.3.2 Swinger Shutdown Not Available — 
Always On
Required
1-6 trips
2 trips
2 trips
4.3.2 Swinger Shutdown 
Disable
33.13 Swinger Bypass Allowed
For non-police response 
zones
Yes
Enabled (all zones)
4.3.3 Fire Alarm 
Verification
33.5 Zone Type
Required Option
FV Type Zone
No
Yes as required 
(unless sensors can 
self verify)
4.6.3 System Test
36.5 Walk Test
Allowed
Test all protection 
devices
N/A
N/A
4.6.5 Communications
36.5 Walk Test
Not Allowed
N/A
N/A
N/A
* Programming at installation may be subordinate to other listed requirements for the intended application. 
** For listed Installations, combined Entry Delay and Transmit Delay should not exceed 1 minute.
Local Bell
All non-fire zones such as Night, Day, Exit, Aux 1 and Aux 2 must be programmed for local bell enabled with a bell 
cutoff time set to a minimum of 6 minutes to provide a cancel window of 5 minutes or greater. This does not apply 
to manually operated zone types such as Panic and Emergency.
The requirements are superseded by any requirements for Commercial Burglar, Household Fire Warning, or 
Household Burglar applications.
Minimum Installation Requirements: SIA CP-01-2010 minimum system installation requirements include an XTLplus, 
an 1135 Wireless Siren, a 9000 Series Wireless keypad, and communication to an SCS-1R receiver.