Allegro
Preliminary 2/5/02
Devices (1st Tier)
(Default = none) Devices include a HW sensor, RF sensors, 
RF touchpads, and other RF devices such as the DTIM. 
Dial Dly
 (Phones)
2nd Tier
(Default = 30 seconds, Parameters = 15-120 seconds) Dial 
Delay determines how much time the user has to stop a panel 
before it sends a false alarm to the central station. 
Alarm reports from sensors in groups 00–03, 10, and 13-20 
can be aborted. To abort the dialing attempt, the user must 
disarm the system within the Dial Dly time setting. Cancel and 
restoral reports from these sensor groups are aborted at the 
same time. The following reports can also be aborted.
System Tamper Alarm/Cancel.
Touchpad Police and Emergency Panic/Cancel.
Forced Arming
Recent Closing and Two Trip Error.
Note 
Fire alarm reports to the central station cannot be aborted.
To set the dial dly:
‰ Enter the desired amount of time (15-120 seconds) and 
then press #.
Pre-Dial String
 (Phones)
2nd Tier
(Default = none, Parameters = 8 digits; 0-9, *, #, pause) This 
feature lets you set up a dialing prefix to disable the call 
waiting feature before the panel makes its first dialing attempt 
to any programmed central monitoring station or downloader 
phone number. The prefix can be up to eight digits. Contact 
your local phone company for call waiting disable numbers 
and characters. See Number 1 and 2 programming on page 7 
for information on how to program * and # characters.
Note 
The pre-dial string is not accessible if a Dealer Code is pro-
grammed and the Installer Code is used to enter installer 
programming mode. To access the pre-dial string option 
when a Dealer Code is programmed, you must enter 
installer programming mode using the Dealer Code. 
To set the pre-dial string:
‰ Enter the desired numbers and then press #
DTMF Dial 
 (Phones)
2nd Tier
(Default = on) This setting determines whether the panel uses 
DTMF tones (on) or pulse (off) for dialing programmed phone 
numbers.
To turn DTMF dialing on or off:
‰ Press # to turn it on or off. 
Table 2: Sensor Group Assigned to Device
Device
Sensor Group
Keyfob or RF Touchpad
1
Portable Panic
1
HW Input
10
DWS
10
PIR
17
Sound
17
Glassguard
17
Smoke
26
Rate of Rise
26
DTIM
36
Table 3: Device Programming
 Device
To Program
Door/Window Sensor (SAW) Press button on top of sensor 
(cover removed).
Motion Sensor
Press button on back of sensor 
(mounting plate removed).
Keychain Touchpad 
(non encrypted)
Press lock & unlock buttons 
until LED blinks.
Keychain Touchpad 
(encrypted)
See Note.
Crystal Sensors
See Note.
DTIM
3-2-1 sequence (on page 6).
Hardwire Sensor
For normally closed - separate 
sensor from magnet.
For normally opened - close 
sensor then reopen.
Note 
When installing crystal sensors and encrypted keychain 
touchpads, use the installation instructions included in 
their packing boxes.
Add 
 (Devices)
2nd Tier
(Default = none) When adding devices, the panel will 
automatically assign the device to a sensor group based on the 
type of device. Table 2 outlines the sensor group assigned to 
each device.
Note 
To override the preassigned sensor number, use the arrow 
keys to skip to the desired sensor number.
To add a device:
1. Press 
#
. The display shows 
ZONE
 {01- 20} - 
TRIP
.
2. Trip the sensor (see Table 3). The panel beeps twice to indi-
cate the sensor was successfully learned into the panel.
3. Repeat step 2 until all desired zones are added.