Siren (1st Tier)
Exit - DL (1st Tier) 
If Exit is selected, the panel returns to active mode. If the 
installer/dealer code is entered, a downloader session will 
begin.
After all installer programming is completed, use the fol-
lowing procedure to exit programming mode.
To exit programming mode:
‰ Press 
until 
EXIT
 - 
DL
  is displayed
 and then press 
#. The 
current time will be displayed.
 
Or
‰ Press * until 
EXIT
 - 
DL
  is displayed
 and then enter 
installer or dealer code to start a Downloader session.
User Programing Menu Items
This section guides you through the user programing menu 
items as they appear in sequence. 
Entering User Programming Mode
There are two tiers of user programming menus. Tier 1 
menus are accessible immediately after entering the pro-
gram mode.
Figure 11. Tier 1 User Programming Menus
Arrows pointing left and right represent the up and down 
arrows on the panel. 
You can enter the user programming mode using the pri-
mary access code. The default primary access code is 
1234.
To enter user programming mode:
With the system disarmed, press 
8 + CODE. This will 
take you to 
CODES
,
 
the first menu item in Tier 1.
Codes (1st Tier) 
Auto Phone Test
 (Reports)
2nd Tier
(Default = off) This setting determines if the panel sends a 
phone test automatically to the central station at Supervisory 
Time. Refer to the “Phone Test Frequency” and “Next Phone 
Test” on page 11.
Note 
For UL Listed installations, the Auto Phone Test feature 
must be set to on.
To turn automatic phone test on or off:
‰ Press # to turn on or off. 
Siren Time Out
(Siren)
2nd Tier
(Default = 4 minutes, Parameters = 1-30) Siren Time-out 
determines how long sirens sound if no one is present to 
disarm the system. 
Note 
For UL Listed installations, the Siren Time-out must be set 
to 4 minutes or more.
To set siren time out:
1. Press 
#
, enter the desired time and then press #
. 
Trouble Beeps
 (Siren)
2nd Tier
(Default = on) When this setting is on, the panel will beep to 
alert users of system trouble.
Note 
For UL Listed installations, Trouble Beeps must be set to 
on.
To turn trouble beeps on or off:
‰ Press # to turn on or off. 
Alarm Volume
 (Siren)
2nd Tier
(Default = 6, Parameters = 0 to 6) This setting allows you to 
adjust the panel’s siren volume. The volume can be set from 0 
to 6, with 0 being the lowest volume.
Note 
Alarm Volume must be set to 6 for UL installations.
To set the alarm volume:
1.
Press #
, enter the desired volume level and then press #
. 
Apartment Manager 
 (Codes)
2nd Tier
(Default = none, Parameters = 4 digits, 0 to 9) The apartment 
manager code functions the same as the primary code within 
the user programming menu, and can arm or disarm the 
system. 
Note 
This code will only be displayed in user programming if the 
apartment manager code was used to enter user program 
mode. 
To program/change apartment manager code:
1. Enter the apartment manager code. The display shows 
CODES
.
2. Press 
#
. The display shows 
MANAGER
3. Press 
to display the current code (if any).
4. Press 
#
, enter the desired code and then press 
#
.
Primary 
 (Codes)
2nd Tier
(Default = 1234, Parameters = 4 digits, 0 to 9) The primary 
code performs all system operations and user programming.
To set the primary code:
1. Press 
to display the current code.
2. Press 
#
, enter the desired code and then press 
#