UTC Fire & Security Americas Corporation Inc 785B-ALGRO User Manual

Page of 31
16
Allegro
Preliminary 2/5/02
User 2, 3, 4
 (Codes)
2nd Tier
(Default = none, Parameters = 4 digits, 0 to 9) User Codes 
performs arming and disarming functions. The user codes 
cannot directly bypass sensors or program the primary code. 
The system allows up to 3 user codes (user 2 - 4). 
To program/change user 2, 3, 4 code:
1. Press 
to display the current user code (if any).
2. Press 
#
, enter the desired user code and then press 
#
Time 
 (Time)
1st Tier
(Default = 00:00) This setting lets you adjust the panel’s clock 
to the correct time. The panel uses a 12-hour clock. 
To set the time:
1. Press 
to display the time.
2. Press 
#
, enter the current time, use the arrow key to select 
am or pm and then press 
#
Phone Test
 (Phone Test)
1st Tier
This setting lets you perform a manual phone test to check the 
phone communication between the panel and the central 
monitoring station. 
Note 
The DTIM and phone number must be programmed before 
the panel will display the Phone Test option.
To perform a phone test:
‰ Press to perform a phone test. The panel will indicate 
if the test was successful or not.
Sensor Test
 (Sensor Test)
1st Tier
This setting lets you perform a manual sensor test to check that 
all the sensors are working properly. 
A DTIM and battery test are performed at the start of the 
sensor test. The panel will display the DTIM zone number 
and beep once for every received transmission.
The panel will beep indicating the number of transmis-
sions received, (see Table B4: “Minimum Beeps,” on 
page 18
), and display the sensor name + 
OK
 to indicate a 
satisfactory test of the sensor. For the first 10 to 20 sec-
onds of test, the volume is set to a lower level.
Panel will automatically leave sensor test after 15 min-
utes.
The panel will display 
ALL
 
OK
 when all sensors have been 
tested.
If Low Lvl reports are on, the panel will send a start of 
test central station report when a sensor test is initiated.
The panel will send an end of test central station report 
when the sensor test ends.
To run a sensor test:
1. Press 
to display the sensor test (
TEST
ZONE
 
XX
). The dis-
play then scrolls thru the untested zones, and beeps indicat-
ing the number of sensor packets received.
2. To trip a sensor, follow the instructions in Table 5.
3. To restart the list, press 1. This will also restart the 15 
minute timer.
Table 5: Sensor Tripping Instructions
Sensor
Do This
DTIM
Initiate a sensor test.
Door/Window
Open the secured door or window
Carbon Monoxide 
Alarm
Unplug the CO Alarm. Plug it back in, 
then press the TEST/RESET button 
until the unit beeps 8 times
Glass Guard
Tap the glass 3 or 4 inches from the 
sensor
Motion Sensor
Avoid the Motion Sensor field of view 
for 5 minutes, then enter its view
Rate-of-Rise Heat 
Detector
Rub your hands together until warm, 
then place one hand on the detector 
for 30 seconds
Shock
Tap the glass twice, away from the 
sensor. Wait at least 30 seconds before 
testing again
Smoke
Press and hold the test button until the 
system sounds transmission beeps
Panic Buttons
Press and hold the appropriate panic 
button(s) for 3 seconds
KeyChain Touchpad
Press and hold LOCK and UNLOCK 
simultaneously for 3 seconds
Remote Handheld 
Touchpad
Press and hold the 2 EMERGENCY 
buttons simultaneously for 3 seconds