UTC Fire & Security Americas Corporation Inc 785B-ALGRO User Manual
16
Allegro
Preliminary 2/5/02
User 2, 3, 4
(Codes)
2nd Tier
(Default = none, Parameters = 4 digits, 0 to 9) User Codes
performs arming and disarming functions. The user codes
cannot directly bypass sensors or program the primary code.
The system allows up to 3 user codes (user 2 - 4).
performs arming and disarming functions. The user codes
cannot directly bypass sensors or program the primary code.
The system allows up to 3 user codes (user 2 - 4).
To program/change user 2, 3, 4 code:
1. Press
#
to display the current user code (if any).
2. Press
#
, enter the desired user code and then press
#
.
Time
(Time)
1st Tier
(Default = 00:00) This setting lets you adjust the panel’s clock
to the correct time. The panel uses a 12-hour clock.
to the correct time. The panel uses a 12-hour clock.
To set the time:
1. Press
#
to display the time.
2. Press
#
, enter the current time, use the arrow key to select
am or pm and then press
#
.
Phone Test
(Phone Test)
1st Tier
This setting lets you perform a manual phone test to check the
phone communication between the panel and the central
monitoring station.
phone communication between the panel and the central
monitoring station.
Note
The DTIM and phone number must be programmed before
the panel will display the Phone Test option.
The DTIM and phone number must be programmed before
the panel will display the Phone Test option.
To perform a phone test:
Press # to perform a phone test. The panel will indicate
if the test was successful or not.
Sensor Test
(Sensor Test)
1st Tier
This setting lets you perform a manual sensor test to check that
all the sensors are working properly.
all the sensors are working properly.
❑
A DTIM and battery test are performed at the start of the
sensor test. The panel will display the DTIM zone number
and beep once for every received transmission.
sensor test. The panel will display the DTIM zone number
and beep once for every received transmission.
❑
The panel will beep indicating the number of transmis-
sions received, (see Table B4: “Minimum Beeps,” on
page 18), and display the sensor name +
sions received, (see Table B4: “Minimum Beeps,” on
page 18), and display the sensor name +
OK
to indicate a
satisfactory test of the sensor. For the first 10 to 20 sec-
onds of test, the volume is set to a lower level.
onds of test, the volume is set to a lower level.
❑
Panel will automatically leave sensor test after 15 min-
utes.
utes.
❑
The panel will display
ALL
OK
when all sensors have been
tested.
❑
If Low Lvl reports are on, the panel will send a start of
test central station report when a sensor test is initiated.
test central station report when a sensor test is initiated.
❑
The panel will send an end of test central station report
when the sensor test ends.
when the sensor test ends.
To run a sensor test:
1. Press
#
to display the sensor test (
TEST
;
ZONE
XX
). The dis-
play then scrolls thru the untested zones, and beeps indicat-
ing the number of sensor packets received.
ing the number of sensor packets received.
2. To trip a sensor, follow the instructions in Table 5.
3. To restart the list, press 1. This will also restart the 15
3. To restart the list, press 1. This will also restart the 15
minute timer.
Table 5: Sensor Tripping Instructions
Sensor
Do This
DTIM
Initiate a sensor test.
Door/Window
Open the secured door or window
Carbon Monoxide
Alarm
Alarm
Unplug the CO Alarm. Plug it back in,
then press the TEST/RESET button
until the unit beeps 8 times
then press the TEST/RESET button
until the unit beeps 8 times
Glass Guard
Tap the glass 3 or 4 inches from the
sensor
sensor
Motion Sensor
Avoid the Motion Sensor field of view
for 5 minutes, then enter its view
for 5 minutes, then enter its view
Rate-of-Rise Heat
Detector
Detector
Rub your hands together until warm,
then place one hand on the detector
for 30 seconds
then place one hand on the detector
for 30 seconds
Shock
Tap the glass twice, away from the
sensor. Wait at least 30 seconds before
testing again
sensor. Wait at least 30 seconds before
testing again
Smoke
Press and hold the test button until the
system sounds transmission beeps
system sounds transmission beeps
Panic Buttons
Press and hold the appropriate panic
button(s) for 3 seconds
button(s) for 3 seconds
KeyChain Touchpad
Press and hold LOCK and UNLOCK
simultaneously for 3 seconds
simultaneously for 3 seconds
Remote Handheld
Touchpad
Touchpad
Press and hold the 2 EMERGENCY
buttons simultaneously for 3 seconds
buttons simultaneously for 3 seconds