5.4. 
REMOTE SETTINGS 
 
After the boot process, the software login is possible. All parameters of the software 
can be changed by the provider to optimize the repeater according to the network 
system. There are two possibilities how to login to the software: 
 
 
locally via a VT100 terminal or a PC with VT100 terminal emulation 
 
remotely via a modem e.g. with the Operations and Maintenance Center (OMC) 
 
5.4.1.  Local Login 
 
The login via VT100 terminal or a PC with VT100 emulation can only be performed at 
the repeater. Open the repeater carefully and ensure that DIP-switch 2 of mode-
switch [1] is in position OFF. Only when DIP-switch 2 is OFF, a local access to the 
software on the control module is possible (see chapter 5.3 DIP-Switches). 
 
Connect the terminal or PC to the RS232 interface on the control module by means 
of a standard RS232 interface cable (see picture below). 
 
 
Terminal or PC 
Control Module SM2009 
9 contact SUB-D-connector 
9 contact SUB-D-connector 
male 
male 
 
Pin                                                                             Pin 
1
2
3
4
5
6
7
8
9
8
9
7
6
1
3
4
5
2
 
 
 
Check the communication mode at the terminal. If necessary, set the following 
parameters: 
 
Bit rate / bit per second: 
9600 baud 
Number of data bit:   
8 bit 
Parity bit: 
 
 
No parity 
Stopbit: 
 
 
1 stopbit