Andrew Wireless Innovations Group RPT-MR703P User Manual

Page of 59
U
SER
´
S MANUAL FOR BAND SELECTIVE REPEATERS 
MR
X
03P 
 
 
User'sManual.doc 
Id.-No.:154999 
Page 32 
22-Jan-01 
 
5.3. 
DIP-SWITCHES 
 
The configuration of the DIP-switches on the control module is factory set. 
 
 
figure 5-2 Control module – Position of the DIP-switches 
 
Mode-switch [1]* 
 
Ext. Alarms-switch [4] 
 
ON 
OFF 
 
 
ON 
OFF 
Manual 
Auto 
 
Ext. Alarm 4 
PSTN (d) 
Remote Mode 
Local Mode 
 
Ext. Alarm 3 
PSTN (c) 
DO NOT USE! 
DO NOT USE! 
 
Ext. Alarm 2 
PSTN (b) 
DO NOT USE! 
Auto 
 
Ext. Alarm 1 
PSTN (a) 
 
 
 
 
 
 
 
Switch for additional inputs [2]** 
 
MOR/MR-switch [3] 
 
ON 
OFF 
 
 
ON 
OFF 
VCC 
O.C. 
 
MR 
MOR 
VCC 
O.C. 
 
MR 
MOR 
VCC 
O.C. 
 
MR 
MOR 
VCC 
O.C. 
 
MR 
MOR 
VCC 
O.C. 
 
MOR 
MR 
VCC 
O.C. 
 
MOR 
MR 
VCC 
O.C. 
 
MOR 
MR 
VCC 
O.C. 
 
MOR 
MR 
Switch 1, 3 and 4 are factory set to position Off 
** 
Switch for additional inputs not in use! 
table 5-2 DIP-switches of control module 
1
2
3
4