Baicells Technologies Co. Ltd. MBS1105 User Manual
Baicells mBS1105 Base Station Installation Guide(V100R001C00,02).docx
8
Installation Environment
3.3
3.3.1 Locational Requirements
Environments with high-temperatures, harmful gases, unstable voltages, volatile
vibrations, loud noises, flames, explosives, and electromagnetic interference (large radar
stations, transmitting stations, transformer substations) are not suitable for the operation
of mBS1105, and thus should be avoided.
Places prone to have impounded water, soaking, leakage, or condensation, should also
be avoided.
Factors like climate, hydrology, geology, earthquake, electric power, and transportation
should be taken into consideration in the construction process so that a proper location
can be chosen to meet the communication engineering environmental requirements, as
well as the technical requirements of network planning and communication equipment.
3.3.2 Environmental Requirements
Table 3-2 gives
the base station’s environmental requirements with regards to
temperature, humidity, and voltage.
Table 3-2 Environmental Requirements of the Base Station
Item
Range
Typical value
Humidity
-40℃~ 55℃
25℃
Relative humidity (no condensation) 0% ~ 100%
5% ~ 95%
Safety voltage
42V ~ 58V
48V
3.3.3 Space Requirements
After the eNodeB has installed, the enough space must be provided for operation and
maintenance. And for heat dissipation and normal running of the eNodeB, the space
must be planed before installation, as shown in Figure 3-1.