Intel S2600JFQ BBS2600JFQ User Manual

Product codes
BBS2600JFQ
Page of 194
BIOS Setup Interface 
Intel®
 
Server Board S2600JF TPS 
 
 
Revision 1.3 
Intel order number G31608-004 
98 
 
 
Main 
Advance
Security 
Server Management 
Boot Options 
Boot Manager 
 
 
 
 
Assert NMI on SERR 
Enabled / Disabled 
Assert NMI on PERR 
Enabled / Disabled 
 
 
Reset on CATERR 
Enabled / Disabled 
Reset on ERR2 
Enabled / Disabled 
 
 
Resume on AC Power Loss 
Stay Off / Last state / Power On 
Power Restore Delay 
Disabled / Auto / Fixed 
Power Restore Delay Value 
25 
Clear System Event Log 
Enabled / Disabled 
 
FRB-2 Enable 
Enabled / Disabled 
 
OS Boot Watchdog Timer  
Enabled / Disabled 
OS Boot Watchdog Timer Policy 
Power off / Reset 
OS Boot Watchdog Timer Timeout 
5 minutes / 10 minutes / 15 minutes / 20 minutes 
 
 
Plug and Play BMC Detection 
Enabled / Disabled 
Shutdown Policy 
Enabled / Disabled 
 
► Console Redirection 
► System Information 
► BMC LAN Configuration
 
 
 
Figure 34. Server Management Screen 
Table 42. Setup Utility 
– Server Management Configuration Screen Fields 
Setup Item 
Options 
Help Text 
Comments 
Assert NMI on 
SERR 
Enabled 
Disabled 
On SERR, generate an NMI and log an 
error. 
Note: [Enabled] must be selected for 
the Assert NMI on PERR setup option 
to be visible. 
 
Assert NMI on 
PERR 
Enabled 
Disabled 
On PERR, generate an NMI and log an 
error. 
Note: This option is only active if the 
Assert NMI on SERR option is 
[Enabled] selected.