Intel S2600JFQ BBS2600JFQ User Manual
Product codes
BBS2600JFQ
BIOS Setup Interface
Intel®
Server Board S2600JF TPS
Revision 1.3
Intel order number G31608-004
100
Setup Item
Options
Help Text
Comments
Shutdown Policy
Enabled
Disabled
Enable/Disable Shutdown Policy
This option is designed for
multiple-node system and to
control the policy that BMC
should shutdown one node if it
detected over-current or over-
temperature condition. The BIOS
and the BMC will synchronize the
policy during the BIOS POST
and current value of the BMC will
be displayed in BIOS Setup.
multiple-node system and to
control the policy that BMC
should shutdown one node if it
detected over-current or over-
temperature condition. The BIOS
and the BMC will synchronize the
policy during the BIOS POST
and current value of the BMC will
be displayed in BIOS Setup.
This option only shows on Node
3 and Node 4
3 and Node 4
Console
Redirection
Redirection
View/Configure console redirection
information and settings.
information and settings.
Takes the user to the Console
Redirection screen.
Redirection screen.
System Information
View system information
Takes the user to the System
Information screen.
Information screen.
BMC LAN
Configuration
Configuration
View/Configure BMC LAN channel and
user settings
user settings
Takes the user to the BMC
configuration screen.
configuration screen.
5.4.2.16
Console Redirection
The Console Redirection screen allows the user to enable or disable Console Redirection for
Remote Management, and to configure the connection options for this feature.
Remote Management, and to configure the connection options for this feature.
To access this screen from the Main screen, select Server Management > Console
Redirection. To move to another screen, press the <Esc> key to return to the Server
Management screen, then select the desired screen.
Redirection. To move to another screen, press the <Esc> key to return to the Server
Management screen, then select the desired screen.
Server Management
Console Redirection
Console Redirection
Disabled / Serial Port A
Flow Control
None / RTS/CTS
Baud Rate
9.6k / 19.2k / 38.4k / 57.6k / 115.2k
Terminal Type
PC-ANSI / VT100 / VT100+ / VT-UTF8
Legacy OS Redirection
Disabled / Enabled
Terminal Resolution
80x24 / 100x31
Figure 35. Console Redirection Screen
Table 43. Setup Utility
– Console Redirection Configuration Fields
Setup Item
Options
Help Text
Console Redirection
Disabled
Serial Port A
Console redirection allows a serial port to be used for server
management tasks.
management tasks.
[Disabled] - No console redirection.
[Serial Port A] - Configure serial port A for console redirection.