Zebra HW46211 User Manual

Page of 275
Page 4-56
110XiIIIPlus Maintenance Manual
13185L-002 Rev. A  1/24/06
Section 4
Maintenance
Remove and Install the Cutter Slotted Link 
1. Refer to 
. Turn the printer Off (O), remove the AC power 
cord and data cables.
2. Refer to 
 and remove the electronics cover.
3. Refer to 
 and remove the power supply.
4. Refer to 
. Remove the E-ring securing the cutter main link to the pivot 
pin in the cutter slotted link.
5. Remove the E-ring, flat washer, and bearing securing the cutter slotted link to the 
pin on the lower drive arm.
6. Remove the E-ring and two flat washers securing the cutter slotted link to the pivot 
post.
7. Remove the slotted link.
8. Install the new slotted link as shown in 
Figure 4-32
.
9. Secure the slotted link to the pivot post with two flat washers and the E-ring.
10. Install the bearing onto the lower drive arm. Place the slot in the slotted link over the 
bearing. Secure the link with a washer and E-ring.
11. Secure the main link to the pivot pin of the slotted link with an E-ring.
12. Apply a small amount of white lithium grease to the slot in the slotted link where the 
bearing will ride. Remove any excess grease to prevent it from contaminating the 
cutter optical sensor.
13. Reinstall the power supply.
14. Reinstall the electronics cover.
15. Reconnect the data cables and AC power cord.
16. Turn the printer On (l).
Caution:
Unless indicated otherwise, turn the printer Off (O) and disconnect the printer 
from the power source before performing the following maintenance.
Caution:
This installation must be performed by a qualified service technician.
Caution:
Wear protective eyewear when removing E-rings, C-clips, snap rings, and 
springs. All of these are under tension and could fly off while being removed.