Zebra HW46211 User Manual
13185L-002 Rev. A 1/24/06
110XiIIIPlus Maintenance Manual
Page 2-43
Operations Overview
Section 2
Set Left Position
The left position controls the initial print position from the left edge of a label (view as the
label exits the printer). The reference default position is to the left edge of the media. Refer
to
. Depending on the width of the media, the label format may begin printing
on the liner or on the platen. To set the position where the format begins printing, change
the left position value.
Press the left oval to move the cursor to the next digit, and press the right oval to change
the ± value and increase the value of the digit (right oval key shifts to the left, left oval key
shifts to the right). The displayed value represents the number of dot positions the format
shifts right or left.
Figure 2-21. Left Position
Press NEXT/SAVE to display HEAD RESISTOR.
Default: 000
Range:
–9999 to +9999 (If a negative value is required, enter the numeric
value first, then change + to –.)
value first, then change + to –.)
LEFT POSITION
000
+
+
Label
Feed
Label
Length
Left
Position
Default
Left
Position
-35 Dot Rows