Hitachi RAF-35RPA RAF35RPA User Manual

Product codes
RAF35RPA
Page of 706
GENERAL DATA 
 
2-5 
 
2.1.4.  DUCT TYPE (RAD-18RPA/25RPA/35RPA/50RPA) 
INDOOR 
Unit 
RAD-18RPA 
RAD-25RPA 
RAD-35RPA 
RAD-50RPA 
Nominal capacity adjustable  
  
Nominal Cooling capacity (min - max) 
kW 
1.8 (0.9~2.5) 
2.5 (0.9-3.0) 
3.5 (0.9-4.0) 
5.0 (0.9-5.6) 
Cooling sensible capacity  
kW 
2.0 
2.5 
3.8 
Nominal Heating capacity (min - max) 
kW 
2.5 (0.9~3.2) 
3.5 (0.9-5.5) 
4.8 (0.9-6.6) 
6.0 (0.9-7.5) 
Noise level cooling (sound pressure) 
(SL / L / M / H) 
dB(A) 
29/31/34/36 
29/31/34/36 
29/31/34/36 
29/32/35/38 
Noise level heating (sound pressure) 
(SL / L / M / H) 
dB(A) 
27/30/33/37 
27/30/33/37 
27/30/33/37 
29/32/35/38 
Noise level (sound power) 
dB(A) 
N/A 
57 
57 
58 
Air flow cooling mode (SL / L / M / H) 
m3/h 
330/372/438/492 
330/390/450/510 
330/390/450/510  330/360/450/510 
Air flow heating mode (SL / L / M / H)  
m3/h 
330/372/450/552 
360/420/480/600 
360/420/480/600  360/420/480/630 
Fan Motor 
20 
20 
20 
20 
Drain pump pressure lift 
cm 
30 max 
30 max 
30 max 
30 max 
Static pressure (SL / L / M / H)  
(nominal conditions SP 00) 
Pa 
Dehumidification 
l/h 
1.4 
1.4 
1.6 
2.8 
Included drain pump 
 
yes 
yes 
yes 
yes 
Max. height available for drain pump 
(RAD/RAI only) 
 
300
 
300 
300 
300 
Dimensions (H x W x D) 
mm 
235x750x400 
235x750x400 
235x750x400 
235x750x400 
Panel dimensions (H x W x D) 
mm 
Weight 
kg 
16.0 
16.0
 
16.0
 
16.0
 
Colour (Munsell Code) 
 
Condensate Drain 
mm 
φ16 
φ16
 
φ16
 
φ16
 
Panel weight 
kg 
Panel reference 
 
Color of the panel (RAL) 
 
Running current 
2.56~2.35 / 
3.2~2.92 
3.19~2.93 / 
4.45~4.08 
5.69~5.22 / 
7.81~7.15 
9.10~8.37 / 
9.87~9.05 
Power supply 
 
35V DC from 
outdoor 
35 V DC from 
outdoor unit 
35 V DC from 
outdoor unit 
35 V DC from 
outdoor unit 
Cable section 
mm² 
N/A 
N/A 
N/A 
N/A 
Piping diameter (Liq / Gas) 
  
1/4" / 3/8" 
1/4" / 3/8" 
1/4" / 3/8" 
1/4" / 1/2" 
Drain diameter (ext) 
mm 
φ16 
φ16 
φ16 
φ16 
Remote control (optional only)  * 
 
SPX-RCKA / 
SPX-RCDA 
SPX-RCKA / 
SPX-RCDA
 
SPX-RCKA / 
SPX-RCDA
 
SPX-RCKA / 
SPX-RCDA
 
Filter 
 
 
 
 
 
ACL Filter 
 
Dimensions (H x W x D) 
mm 
Pre-filter (Standard / Optional) 
 
Washable/- 
Washable/- 
Washable/- 
Washable/-
 
*
more information regarding remote control can be found in Chapter 9 
 
NOTE: 
1.  The nominal cooling and heating capacity is the 
combined capacity of the HITACHI standard split 
system, and are based on the ISO 5151.
 
 
2.  The Sound Pressure Level is based on the following 
conditions:  
0.8 meter beneath indoor height center 
1.5 meter from Discharge grille 
The above data was measured in an anechoic 
chamber. Please take into consideration reflected 
sound of your specific site 
 
Operation Conditions 
Cooling 
Heating 
 
Indoor Air Inlet Temperature
 
dB 
27.0 °C
 
20.0 °C 
 
WB 
19.0 °C
 
 
 
Outdoor Air Inlet Temperature
 
dB 
35.0 °C
 
7.0 °C
 
 
WB 
 
6.0 °C 
 
Piping Length: 5.0 meters; Piping Lift: 0 meter 
dB: Dry Bulb; WB: Wet Bulb