Hitachi RAF-35RPA RAF35RPA User Manual
Product codes
RAF35RPA
GENERAL DATA
2-17
2.2.7. WALL TYPE (RAK-25PXA/35PXA/50PXA)
INDOOR
Unit
RAK-25PXA
RAK-35PXA
RAK-50PXA
Nominal capacity adjustable
-
-
-
Nominal Cooling capacity (min - max)
kW
2.5(0.9-3.1)
3.5(0.9-4.0)
5.0 (0.9-5.2)
Cooling sensible capacity
kW
2.1
2.6
3.4
Nominal Heating capacity (min - max)
kW
3.4(0.9-4.4)
4.2(0.9-5.0)
6.3 (0.9-7.9)
Noise level cooling (sound pressure)
(SL / L / M / H)
(SL / L / M / H)
dB(A)
20/26/32/40
22/29/35/42
25/31/39/47
Noise level heating (sound pressure)
(SL / L / M / H)
(SL / L / M / H)
dB(A)
20/27/33/40
22/30/35/42
25/31/39/48
Noise level (sound power)
dB(A)
54
56
60
Air flow cooling mode (SL / L / M / H)
m
3
/h
210/270/370/480
230/300/400/520
288/408/552/690
Air flow heating mode (SL / L / M / H)
m
3
/h
200/330/420/570
220/360/450/610
288/438/576/780
Fan Motor
W
25
25
25
Drain pump pressure lift
cm
-
-
-
Static pressure (SL / L / M / H)
(nominal conditions SP 00)
(nominal conditions SP 00)
Pa
-
-
-
Dehumidification
l/h
1.4
1.6
3.0
Included drain pump
-
-
-
Max. height available for drain pump
(RAD/RAI only)
(RAD/RAI only)
-
-
-
Dimensions (H x W x D)
mm
295×795×198
295×795×198
295x795x198
Panel dimensions (H x W x D)
mm
-
-
-
Weight
kg
10
10
10.0
Colour (Munsell Code)
White (ZYYD6)
White (ZYYD6)
White (ZYYD6)
Condensate Drain
mm
φ16
φ16
φ16
Panel weight
kg
-
-
-
Panel reference
-
-
-
Color of the panel (RAL)
-
-
-
Running current
A
2.97/3.82
4.21/4.62
6.83/7.66
Power supply
35 V DC from outdoor
unit
35 V DC from outdoor
unit
36 V DC from outdoor
unit
Cable section
mm²
0.75x2
0.75x2
2.0x3
Piping diameter (Liq / Gas)
1/4” - 3/8”
1/4” - 3/8”
1/4" / 1/2"
Drain diameter (ext)
mm
φ16
φ16
φ16
Remote control (standard/optional) *
RAR-5E3/SPX-RCDB
RAR-5E3/SPX-RCDB
RAR-5E3/SPX-RCDB
Filter
ACL Filter
Wasabi
Wasabi
Wasabi
Dimensions (H x W x D)
mm
48x243x5
48x243x5
48x243x5
Pre-filter (Standard / Optional)
Nano Stainless/-
Nano Stainless/-
Nano Stainless/-
NOTE:
1. The nominal cooling and heating capacity is the
combined capacity of the HITACHI standard split
system, and are based on the ISO 5151.
system, and are based on the ISO 5151.
2. The Sound Pressure Level is based on the following
conditions:
-
Half height of the unit
-
1 meter from Discharge grille
The above data was measured in an anechoic
chamber. Please take into consideration reflected
sound of your specific site
chamber. Please take into consideration reflected
sound of your specific site
Operation Conditions
Cooling
Heating
Indoor Air Inlet Temperature
dB
27.0 °C
20.0 °C
WB
19.0 °C
Outdoor Air Inlet Temperature
dB
35.0 °C
7.0 °C
WB
6.0 °C
Piping Length: 5.0 meters; Piping Lift: 0 meter
dB: Dry Bulb; WB: Wet Bulb