Hitachi RAF-35RPA RAF35RPA User Manual
Product codes
RAF35RPA
GENERAL DATA
2-26
2.2.16. FLOOR TYPE (RAC-25FXA/35FXA/50FXA)
OUTDOOR
UNIT
RAC-25FXA
RAC-35FXA
RAC-50FXA
Minimum / Maximum indoor units
connectable
connectable
-
-
-
Minimum / Maximum connected
capacity
capacity
-
-
-
Nominal Cooling capacity (min - max)
kW
2.5(0.9-3.1)
3.5(0.9-4.0)
5.0 (0.9-5.2)
Nominal Heating capacity (min - max)
kW
3.4(0.9-4.4)
4.5(0.9-5.0)
6.5 (0.9-8.1)
Nominal cooling power input (min -
max)
max)
kW
0.580(155-1,160)
1.020(0.155-1.380)
1.560(0.155-1.950)
Nominal heating power input (min -
max)
max)
kW
0.79(0.115-1.170)
1.220(0.115-1.350)
1.780(0.155-2.100)
EER / COP
4.31/4.30
3.43/3.69
3.21/3.65
SEER / SCOP
6.4/4.2
6.4/4.1
6.0/4.2
Energy class (SEER/SCOP)
A++/A+
A++/A+
A+/A+
Noise level cooling (sound pressure)
dB(A)
45
46
50
Noise level heating (sound pressure)
dB(A)
47
48
52
Noise level (sound power)
dB(A)
62
63
65
Air flow (Cooling / Heating)
m
3
/h
1860 / 1620
1920 / 1620
1950 /1750
Static pressure (nominal conditions,
maximum)
maximum)
Pa
-
-
-
Dimensions (H x W x D)
mm
590x750x215
590x750x215
600x792x299
Weight
kg
35.0
35.0
42
Colour (Munsell Code)
T-Beige (ZYY95)
Power supply
230V / 1Ph / 50Hz
230V / 1Ph / 50Hz
230V / 1Ph / 50Hz
Recommended fuse size
A
16
16
16
Starting current
A
-
-
-
Running current
A
2.66-2.55/3.63-3.47
4.68-4.48/5.60-5.36
7.16-6.85/8.17-7.82
Cable section
mm
2
-
-
-
Interconnection between indoor unit
and outdoor unit
and outdoor unit
mm
2
1.6 or 2.0
1.6 or 2.0
1.6 or 2.0
Piping diameter (Liq / Gas)
1/4" / 3/8"
1/4" / 3/8"
1/4" / 1/2"
Minimum piping length
m
5.0
5.0
5
Maximum piping length / height
difference
difference
m
20 / 10
20 / 10
30 / 10
Current quantity of refrigerant /
Chargeless
Chargeless
kg
0.87
0.87
1.45
Chargeless / Additional refrigerant
charge
charge
m / g/m
20/-
20/-
30/-
Working range (cooling / heating)
°C
-10 ~ 43 / -15 ~ 21
-10 ~ 43 / -15 ~ 21
-10 ~ 43 / -15 ~ 21
Refrigerant
R410A
R410A
R410A
Condenser Fan
Propeller Fan
Compressor
Type
Scroll
Scroll
Scroll
Oil Type
POE
POE
HAF68D1
Oil Charge
ml
380
380
420
Coil Resistance
1.069 at 20
C
1.069 at 20
C
1.069 at 20
C
1.3 at 75
C
1.3 at 75
C
1.3 at 75
C
Quantity
1
1
1
NOTE:
1. The Sound Pressure Level is based on the following conditions:
-
1 meter from the unit front surface and 1 meter from floor level
The above data was measured in an anechoic chamber. Please take into consideration reflected sound of your specific
site
site