Eaton CMMZ-00/08 106291 User Manual

Product codes
106291
Page of 80
EATON RF SYSTEM
3
Wiring Examples for Switching Actuator CSAU-01/02, CSAU-01/04
e.g. lamps,
pumps,
fans, 
sound signal
emitters
release signals for
other control devices
e.g. garage door
e.g. release for
heating, 
air conditioning 
or ventilation
e.g. dimming via a
push-button dimmer
input 
e.g. electric heating
(heating contactor)
e.g. electric sauna 
Switching fluorescent lamps with a CSAU-01/02 actuator
SA cycles
Total capacitor value
55000
25µF
26000
55µF
14000
90µF
8000
100µF
7000
130µF
The numbers of SA cycles specified are approximate values and may vary depending on the local conditions prevailing in each case. The
total capacitor value is the sum of the individual capacitor values according to the type and number of fluorescent lamps compensated in
parallel (see table below). The max. load current of the actuator must not be exceeded. The max. number of cycles selected depends on the
type of application and hence determines the number of fluorescent lamps to be switched via an actuator. 
Lamp capacity