Fluke Fluke 4325162 User Manual

Product codes
4325162
Page of 56
 
Earth/Ground Tester 
 
Display 
11 
Table 5. Display Descriptions (cont.) 
Function Displays 
Condition 
Note 
 
 
edw035.eps 
Aux. current spike- 
resistance is being 
tested. 
Wait for test result. 
 
 
edw036.eps 
Earth resistance is 
being tested. 
Wait for test result. 
 
ST
 
edw037.eps 
Measuring circuit of 
earth and 
auxiliary-earth 
electrode 
disconnected. 
Check lead connection 
on earth spikes 
measuring lead might 
be defective. 
 
ST
 
edw038.eps 
Measuring circuit of 
earth and probe 
electrode 
disconnected. 
Check lead connection 
on earth spikes 
measuring lead might 
be defective. 
 
 
edw039.eps 
Maximum allowable 
error exceeded 
because of too high 
sense or aux earth 
spike resistance. 
Try to moisten soil or 
connect 2nd aux earth 
spike in parallel. 
After 
"START" 
 
edw040.eps 
Measuring range 
exceeded. 
Measured value is 
higher than 300 k
Ω
 
 
edw041.eps 
Display of measured 
value exceeds LIMIT. 
Measured value is 
higher than set LIMIT.