R3008SB CH MODE
The R3008SB receiver is a very versatile 
unit.  It has 8 PWM outputs, S.BUS and S.BUS2 
outputs.  Additionally the PWM outputs can be 
changed from channels 1-8 to channels 9-10.  If 
you only desire to use it as an 7 channel receiver 
(without S.BUS), it can be used without any 
setting changes.
Danger
Don't touch wiring. 
* There is a danger of receiving an electric shock.
Don't short-circuit the battery terminals.
* A short circuit across the battery terminals may cause 
abnormal heating, fire and burns.
Please double check your polarity ( + and 
- ) when hooking up your connectors. 
* If + and - of wiring are mistaken, it will damage, 
ignite and explode.
Don’t connect to Extra Voltage before 
turning on a receiver power supply.
How to change the R3008SB Channel mode
The R3008SB is capable of changing its channel 
allocations as described in the table below.   
1. Turn on the receiver.  (At this moment, the 
transmitter should be off.)  Then, LED blinks 
RED in about 3 seconds. Next, wait until it 
becomes solid RED.
2. Press and hold the Mode Switch more than 
5 seconds.
3. Release the button when the LED blinks 
RED and GREEN simultaneously.
4. The receiver is now in the "Operation 
CH Set" mode.  At this moment, the LED 
indicates current set status through flashing 
a pattern that corresponds to the CH 
mode.
*Cannot exit this CH setting mode before the operation 
mode is fixed.
*See the below table that shows correspondence between 
"CH mode" and way of flashing LED.
*Default CH mode is "Mode B".
5. By pressing the Mode Switch, the operation 
CH is switched sequentially as "Mode C"  
"Mode D"  "Mode A"....
6. The operation mode will be set by pressing 
the Mode Switch more than 2 seconds at 
the desired CH mode.
7. Release the button when the LED blinks 
RED and GREEN simultaneously. Then, the 
operation CH is fixed.
8. After confirming the operation CH mode 
is changed, turn off and back on the 
receiver power.
*The “Operation CH Set” mode cannot be changed during 
the receiver communicates to the transmitter.
Output 
connector
Channel
Mode A
1 ~ 8CH
Mode B
1 ~ 7CH
Mode C
9 ~ 10CH
Mode D
9 ~ 10CH
1
1
1
9
9
2
2
2
10
10
3
3
3
4
4
4
5
5
5
6
6
6
7/B
7
7
8/SB
8
S.BUS
S.BUS
Red LED blink
1 time
2 time
3 time
4 time
R3008SB CH Mode table
Default CH mode
Extra Voltage Connector
Use this connector when using a voltage 
telemetry device to send the battery voltage (DC0 
~ 70V) from the receiver to the transmitter. 
You will need to purchase the optional External 
Voltage input cable (CA-RVIN-700) FUTM5551.
You can then make a cable with an extra 
connector to the External voltage connector.