Microchip Technology MA330018 Data Sheet
dsPIC33FJ32MC302/304, dsPIC33FJ64MCX02/X04 AND dsPIC33FJ128MCX02/X04
DS70291G-page 370
© 2007-2012 Microchip Technology Inc.
FIGURE 31-2:
EXTERNAL CLOCK TIMING
Q1
Q2
Q3
Q4
OSC1
CLKO
Q1
Q2
Q3 Q4
OS20
OS25
OS30
OS30
OS40
OS41
OS31
OS31
TABLE 31-16: EXTERNAL CLOCK TIMING REQUIREMENTS
AC CHARACTERISTICS
Standard Operating Conditions: 3.0V to 3.6V
(unless otherwise stated)
Operating temperature
(unless otherwise stated)
Operating temperature
-40°C
≤ T
A
≤ +85°C for Industrial
-40°C
≤ T
A
≤ +125°C for Extended
Param
No.
Symb
Characteristic
Min
Typ
(1)
Max
Units
Conditions
OS10
F
IN
External CLKI Frequency
(External clocks allowed only
(External clocks allowed only
in EC and ECPLL modes)
DC
—
40
MHz
EC
Oscillator Crystal Frequency
3.5
10
—
3.5
—
—
—
—
—
—
—
10
40
33
10
40
33
10
MHz
MHz
MHz
kHz
MHz
XT
HS
Sosc
AUX_OSC_F
HS
Sosc
AUX_OSC_F
IN
OS20
T
OSC
T
OSC
= 1/F
OSC
12.5
—
DC
ns
—
OS25
T
CY
Instruction Cycle Time
(2)
25
—
DC
ns
—
OS30
TosL,
TosH
TosH
External Clock in (OSC1)
High or Low Time
0.375 x T
OSC
—
0.625 x T
OSC
ns
EC
OS31
TosR,
TosF
TosF
External Clock in (OSC1)
Rise or Fall Time
—
—
20
ns
EC
OS40
TckR
CLKO Rise Time
(3)
—
5.2
—
ns
—
OS41
TckF
CLKO Fall Time
(3)
—
5.2
—
ns
—
OS42
G
M
External Oscillator
Transconductance
(4)
14
16
18
mA/V V
DD
= 3.3V
T
A
= +25ºC
Note 1: Data in “Typ” column is at 3.3V, 25°C unless otherwise stated.
2: Instruction cycle period (T
CY
) equals two times the input oscillator time-base period. All specified values
are based on characterization data for that particular oscillator type under standard operating conditions
with the device executing code. Exceeding these specified limits may result in an unstable oscillator
operation and/or higher than expected current consumption. All devices are tested to operate at “min.”
values with an external clock applied to the OSC1/CLKI pin. When an external clock input is used, the
“max.” cycle time limit is “DC” (no clock) for all devices.
with the device executing code. Exceeding these specified limits may result in an unstable oscillator
operation and/or higher than expected current consumption. All devices are tested to operate at “min.”
values with an external clock applied to the OSC1/CLKI pin. When an external clock input is used, the
“max.” cycle time limit is “DC” (no clock) for all devices.
3: Measurements are taken in EC mode. The CLKO signal is measured on the OSC2 pin.
4: Data for this parameter is Preliminary. This parameter is characterized, but not tested in manufacturing.
4: Data for this parameter is Preliminary. This parameter is characterized, but not tested in manufacturing.