Microchip Technology MA330018 Data Sheet

Page of 460
© 2007-2012 Microchip Technology Inc.
DS70291G-page  371
dsPIC33FJ32MC302/304, dsPIC33FJ64MCX02/X04 AND dsPIC33FJ128MCX02/X04
TABLE 31-17: PLL CLOCK TIMING SPECIFICATIONS (V
DD
 = 3.0V TO 3.6V)  
AC CHARACTERISTICS
Standard Operating Conditions: 3.0V to 3.6V (unless otherwise stated)
Operating temperature
-40°C 
≤  T
A
 
≤  +85°C for Industrial 
-40°C 
≤  T
A
 
≤  +125°C for Extended
Param
No.
Symbol
Characteristic
Min
Typ
(1)
Max
Units
Conditions
OS50
F
PLLI
PLL Voltage Controlled 
 
Oscillator (VCO) Input 
 
Frequency Range
0.8
8
MHz ECPLL, XTPLL modes
OS51
F
SYS
On-Chip VCO System 
 
Frequency
100
200
MHz
OS52
T
LOCK
PLL Start-up Time (Lock Time)
0.9
1.5
3.1
mS
OS53
D
CLK
CLKO Stability (Jitter)
(2)
-3
0.5
3
%
Measured over 100 ms 
period
Note 1: Data in “Typ” column is at 3.3V, 25°C unless otherwise stated. Parameters are for design guidance only 
and are not tested.
2: These parameters are characterized by similarity, but are not tested in manufacturing. This specification is 
based on clock cycle by clock cycle measurements. To calculate the effective jitter for individual time bases 
or communication clocks use this formula:
Peripheral Clock Jitter
D
CLK
F
OSC
Peripheral Bit Rate Clock
--------------------------------------------------------------
------------------------------------------------------------------------
=
For example: Fosc = 32 MHz, D
CLK
 = 3%, SPI bit rate clock, (i.e., SCK) is 2 MHz.
SPI SCK Jitter
D
CLK
32 MHz
MHz
--------------------
------------------------------
3%
16
----------
3%
4
--------
0.75%
=
=
=
=
TABLE 31-18: AC CHARACTERISTICS: INTERNAL RC ACCURACY 
AC CHARACTERISTICS
Standard Operating Conditions: 3.0V to 3.6V (unless otherwise stated)
Operating temperature
-40°C 
 TA 
≤ 
+85°C for industrial
 
-40°C 
≤  T
A
 
≤  +125°C for Extended
Param 
No.
Characteristic
Min
Typ
Max
Units
Conditions
Internal FRC Accuracy @ FRC Frequency = 7.37 MHz
(1)
F20
FRC
-2
+2
%
-40°C 
≤ T
A
 
≤ +85°C
V
DD
 = 3.0-3.6V
FRC
-5
+5
%
-40°C 
≤  T
A
 
≤  +125°C
V
DD
 = 3.0-3.6V
Note 1: Frequency calibrated at 25°C and 3.3V. TUN bits can be used to compensate for temperature drift.
TABLE 31-19: INTERNAL RC ACCURACY
AC CHARACTERISTICS
Standard Operating Conditions: 3.0V to 3.6V (unless otherwise stated)
Operating temperature
-40°C 
≤  T
A
 
≤  +85°C for Industrial 
-40°C 
≤  T
A
 
≤  +125°C for Extended
Param
No.
Characteristic
Min
Typ
Max
Units
Conditions
LPRC @ 32.768 kHz
(1)
F21
LPRC
-20
±6
+20
%
-40°C 
≤  T
A
 
≤  +85°C
V
DD
 = 3.0-3.6V
LPRC
-30
+30
%
-40°C 
≤  T
A
 
≤  +125°C
V
DD
 = 3.0-3.6V
Note 1: Change of LPRC frequency as V
DD
 changes.