Microchip Technology MA330031-2 Data Sheet

Page of 530
dsPIC33EPXXXGP50X, dsPIC33EPXXXMC20X/50X AND PIC24EPXXXGP/MC20X
DS70000657H-page 224
 2011-2013 Microchip Technology Inc.
bit 4-0
SYNCSEL<4:0>:
 Trigger/Synchronization Source Selection bits
11111 
= OCxRS compare event is used for synchronization
11110 
= INT2 pin synchronizes or triggers OCx
11101 
= INT1 pin synchronizes or triggers OCx
11100 
= CTMU module synchronizes or triggers OCx
11011 
= ADC1 module synchronizes or triggers OCx
11010 
= CMP3 module synchronizes or triggers OCx
11001 
= CMP2 module synchronizes or triggers OCx
11000 
= CMP1 module synchronizes or triggers OCx
10111 
= Reserved
10110 
= Reserved
10101 
= Reserved
10100 
= Reserved
10011 
= IC4 input capture event synchronizes or triggers OCx
10010 
= IC3 input capture event synchronizes or triggers OCx
10001 
= IC2 input capture event synchronizes or triggers OCx
10000 
= IC1 input capture event synchronizes or triggers OCx
01111 
= Timer5 synchronizes or triggers OCx
01110 
= Timer4 synchronizes or triggers OCx
01101 
= Timer3 synchronizes or triggers OCx
01100 
= Timer2 synchronizes or triggers OCx (default)
01011 
= Timer1 synchronizes or triggers OCx
01010 
= PTGOx synchronizes or triggers OCx
01001 
= Reserved
01000 
= Reserved
00111 
= Reserved
00110 
= Reserved
00101 
= Reserved
00100 
= OC4 module synchronizes or triggers OCx
)
00011 
= OC3 module synchronizes or triggers OCx
)
00010 
= OC2 module synchronizes or triggers OCx
)
00001 
= OC1 module synchronizes or triggers OCx
)
00000 
= No Sync or Trigger source for OCx
REGISTER 15-2:
OCxCON2: OUTPUT COMPARE x CONTROL REGISTER 2 (CONTINUED)
Note 1:
Do not use the OCx module as its own Synchronization or Trigger source.
2:
When the OCy module is turned OFF, it sends a trigger out signal. If the OCx module uses the OCy 
module as a Trigger source, the OCy module must be unselected as a Trigger source prior to disabling it.
3:
Each Output Compare x module (OCx) has one PTG Trigger/Synchronization source. See 
Section 24.0 
“Peripheral Trigger Generator (PTG) Module”
 for more information.
PTGO0 = OC1
PTGO1 = OC2
PTGO2 = OC3
PTGO3 = OC4