Microchip Technology MA330025-1 Data Sheet

Page of 622
 2009-2012 Microchip Technology Inc.
DS70616G-page 291
dsPIC33EPXXX(GP/MC/MU)806/810/814 and PIC24EPXXX(GP/GU)810/814
REGISTER 15-2:
OCxCON2: OUTPUT COMPARE x CONTROL REGISTER 2
R/W-0
R/W-0
R/W-0
R/W-0
U-0
U-0
U-0
R/W-0
FLTMD
FLTOUT
FLTTRIEN
OCINV
OC32
bit 15
bit 8
R/W-0
R/W-0 HS
R/W-0
R/W-0
R/W-1
R/W-1
R/W-0
R/W-0
OCTRIG
TRIGSTAT
OCTRIS
SYNCSEL<4:0>
bit 7
bit 0
Legend:
HS = Hardware Settable bit
R = Readable bit
W = Writable bit
U = Unimplemented bit, read as ‘0’
-n = Value at POR
‘1’ = Bit is set
‘0’ = Bit is cleared
x = Bit is unknown
bit 15
FLTMD: Fault Mode Select bit 
1 = Fault mode is maintained until the Fault source is removed; the corresponding OCFLTx bit is
cleared in software and a new PWM period starts
0 = Fault mode is maintained until the Fault source is removed and a new PWM period starts 
bit 14
FLTOUT: Fault Out bit
1 = PWM output is driven high on a Fault
0 = PWM output is driven low on a Fault
bit 13
FLTTRIEN: Fault Output State Select bit 
1 = OCx pin is tri-stated on Fault condition
0 = OCx pin I/O state defined by FLTOUT bit on Fault condition
bit 12
OCINV: OCMP Invert bit 
1 = OCx output is inverted
0 = OCx output is not inverted
bit 11-9
Unimplemented: Read as ‘0’
bit 8
OC32: Cascade Two OCx Modules Enable bit (32-bit operation)
1 = Cascade module operation is enabled
0 = Cascade module operation is disabled
bit 7
OCTRIG: OCx Trigger/Sync Select bit
1 = Triggers OCx from source designated by SYNCSELx bits
0 = Synchronizes OCx with source designated by SYNCSELx bits
bit 6
TRIGSTAT: Timer Trigger Status bit
1 = Timer source has been triggered and is running
0 = Timer source has not been triggered and is being held clear
bit 5
OCTRIS: OCx Output Pin Direction Select bit
1 = OCx is tri-stated
0 = Output compare module drives the OCx pin
Note 1: Do not use the OCx module as its own Sync or Trigger source.
2:
When the OCy module is turned OFF, it sends a trigger out signal. If the OCx module uses the OCy module 
as a Trigger source, the OCy module must be unselected as a Trigger source prior to disabling it.