TABLE 32-57: ADC CONVERSION (12-BIT MODE) TIMING REQUIREMENTS 
AC CHARACTERISTICS
Standard Operating Conditions: 3.0V to 3.6V (see Note 
)
(unless otherwise stated)
Operating temperature
-40°C 
  T
A
 
  +85°C for Industrial
-40°C 
  T
A
 
  +125°C for Extended
Param. Symbol
Characteristic
Min.
Typ.
(
)
Max.
Units
Conditions
Clock Parameters
AD50
T
AD
ADC Clock Period
117.6
ns
AD51
t
RC
ADC Internal RC Oscillator 
Period
250
ns
Conversion Rate
AD55
t
CONV
Conversion Time
14 T
AD
ns
AD56
F
CNV
Throughput Rate
500
Ksps
AD57
T
SAMP
Sample Time
3 T
AD
Timing Parameters
AD60
t
PCS
Conversion Start from Sample 
Trigger
(
)
2 T
AD
3  T
AD
Auto-Convert Trigger 
not selected
AD61
t
PSS
Sample Start from Setting
Sample (SAMP) bit
2 T
AD
3  T
AD
AD62
t
CSS
Conversion Completion to
Sample Start (ASAM = 1)
(
)
0.5 T
AD
AD63
t
DPU
Time to Stabilize Analog Stage
from ADC Off to ADC On
(
)
20
s
See Note 
Note 1: Because the sample caps will eventually lose charge, clock rates below 10 kHz may affect linearity 
performance, especially at elevated temperatures.
2: These parameters are characterized but not tested in manufacturing.
3: The t
DPU
 parameter is the time required for the ADC module to stabilize at the appropriate level when the 
module is turned on (ADON (ADxCON1<15>) = 1). During this time, the ADC result is indeterminate.
4: Device is functional at V
BORMIN
 < V
DD
 < V
DDMIN
. Analog modules: ADC, Comparator and DAC will have 
degraded performance. Device functionality is tested but not characterized. Refer to Paramete
 in 