TABLE 30-61: ADC CONVERSION (10-BIT MODE) TIMING REQUIREMENTS 
AC CHARACTERISTICS
Standard Operating Conditions: 3.0V to 3.6V
(unless otherwise stated)
)
Operating temperature
-40°C 
 T
A
 
 +85°C for Industrial
-40°C 
 T
A
 
 +125°C for Extended
Param 
No.
Symbol
Characteristic
Min.
Typ.
Max.
Units
Conditions
Clock Parameters
AD50
T
AD
ADC Clock Period
76
ns
AD51
t
RC
ADC Internal RC Oscillator Period
)
250
ns
Conversion Rate
AD55
t
CONV
Conversion Time
12 T
AD
AD56
F
CNV
Throughput Rate
1.1
Msps Using simultaneous 
sampling
AD57a T
SAMP
Sample Time when Sampling any 
ANx Input
2 T
AD
AD57b T
SAMP
Sample Time when Sampling the 
Op Amp Outputs (Configuration A 
and Configuration B)
(
,
4 T
AD
Timing Parameters
AD60
t
PCS
Conversion Start from Sample
Trigger
(
)
2 T
AD
3  T
AD
Auto-convert trigger is 
not selected
AD61
t
PSS
Sample Start from Setting
Sample (SAMP) bit
))
2 T
AD
3  T
AD
AD62
t
CSS
Conversion Completion to
Sample Start (ASAM = 1)
(
)
0.5  T
AD
AD63
t
DPU
Time to Stabilize Analog Stage 
from ADC Off to ADC On
(
20
s
)
Note 1:
Device is functional at V
BORMIN
 < V
DD
 < V
DDMIN
, but will have degraded performance. Device functionality 
is tested, but not characterized. Analog modules (ADC, op amp/comparator and comparator voltage 
reference) may have degraded performance. Refer to Parameter 
 in 
 for the minimum 
and maximum BOR values.
2:
Parameters are characterized but not tested in manufacturing.
3:
Because the sample caps will eventually lose charge, clock rates below 10 kHz may affect linearity 
performance, especially at elevated temperatures.
4:
 for configuration information.
5:
 for configuration information.
6:
The parameter, t
DPU
, is the time required for the ADC module to stabilize at the appropriate level when the 
module is turned on (ADON (AD1CON1<15>) = 1). During this time, the ADC result is indeterminate.
TABLE 30-62: DMA MODULE TIMING REQUIREMENTS
AC CHARACTERISTICS
Standard Operating Conditions: 3.0V to 3.6V
(unless otherwise stated)
Operating temperature
-40°C
 T
A
 
 +85°C for Industrial
-40°C
 T
A
 
 +125°C for Extended
Param 
No.
Characteristic
Min.
Typ.
Max.
Units
Conditions
DM1
DMA Byte/Word Transfer Latency
1 T
CY(
ns
Note 1:
These parameters are characterized, but not tested in manufacturing.