Voltcraft CO-100 Room Air Meter CO-100 Data Sheet

Product codes
CO-100
Page of 88
37
¼
Defective calibration can occur in particular if the CO
2
 concentration fluctuates during
calibration.
Eliminate any interfering influences and perform calibration again.
• Briefly press „ENTER“ to leave calibration mode. The CO
2
 meter returns to normal
display.
g) Datalogger Function (Data Memory)
The CO
2
 meter automatically stores the measured CO
2
 (carbon dioxide), temperature and
humidity values for the last 24 hours at 30-minute intervals.
The oldest dataset is overwritten each time. All in all, a maximum of 48 datasets can be
stored.
¼
The data remains stored even if the CO
2
 meter is disconnected from the power
supply.
Proceed as follows to display the data:
• Briefly press the „MODE“ button repeatedly (from the normal operating mode) until
„DATALOGGER“ flashes on the display.
• Briefly press the button „ENTER“; the last dataset is displayed. The top display line
alternates between CO
2
 concentration and dataset number.
Latest dataset = # 1 (30 minutes ago)
Oldest dataset = #48 (24 hours ago)
• Select a dataset with the arrows „“ and „“.
• Briefly press „ENTER“ to leave dataset display. The CO
2
 meter returns to normal display.