Bosch AXT 25 TC 0 600 803 300 Data Sheet

Product codes
0 600 803 300
Page of 89
F 016 L70 735 | (11.4.11)
Bosch Power Tools
14 | English 
Technical Data
Noise/Vibration Information
Declaration of Conformity
Equipment category: 50
Technical file at:
Bosch Lawn and Garden Ltd., PT-LG/EAE,
Stowmarket, Suffolk IP14 1EY, England
Robert Bosch GmbH, Power Tools Division
D-70745 Leinfelden-Echterdingen
24.02.2011
Assembly
For Your Safety
f
Warning! Switch off, remove plug from 
mains before adjusting, cleaning or if ca-
ble is cut, damaged or entangled.
Observe correct mains voltage: The voltage 
of the power source must agree with the volt-
age specified on the nameplate of the unit. 
Equipment marked with 230 V can also be 
connected to 220 V or 240 V.
The circuit must at least be protected as fol-
lows:
AXT 22 D/25 D/23 TC/25 TC  =  13 A
An extension cable with a cross section that is 
too small causes a distinct reduction in the 
performance capabilities of the machine. For 
cables to 25 m in length, a cross section of at 
least  3 x 1.5 mm
2
 is required, for cables more 
than 25 m in length, the cross section must be 
at least 2.5 mm
2
.
f
WARNING! Inadequate extension cables 
can be dangerous. Extension cable, plug 
and socket must be of watertight con-
struction and intended for outdoor use.
Cable connections should be kept dry and off 
the ground.
Quiet-shredder
AXT 22 D
AXT 25 D AXT 23 TC AXT 25 TC
Article number
3 600 ...
H03 0..
H03 1..
H03 2..
H03 3..
Power consumption, S 6 
(40/60 s)
1)
W
2200
2500
2300
2500
Power consumption, S 1
W
2000
2300
2100
2300
No-load speed
min
-1
40
40
40
40
Cutting system
Drum
Drum
Turbine
Turbine
Capacity, max.
kg/h
180
2)
190
2)
215
2)
230
2)
Branch diameter, max.
mm
38
2)
40
2)
42
2)
45
2)
Collection box
l
53
53
53
53
Weight according to 
EPTA-Procedure 01/2003
kg
31.3
31.3
30.5
30.5
Protection class
/I
/I
/I
/I
1)
The S 6 operating mode (40 %) indicates a load profile of 40 s load and 60 s idle time. For practical applica-
tion, continuous operation is permitted.
2)
Depending on the hardness of the wood.
Starting cycles generate brief voltage drops. Interference with other equipment/machines may occur in case of 
unfavourable mains system conditions. Malfunctions are not to be expected for system impedances below 
0.36 ohm.
Measured sound values determined according to 2000/14/EC 
(1.60 m height, 1 m distance away).
3 600 ... H03 0..
H03 1..
H03 2..
H03 3..
Typically the A-weighted noise levels of the product are:
Sound pressure level
Sound power level
Uncertainty K
Wear hearing protection!
dB(A)
dB(A)
dB
81
89
=3
82
90
=2
3 600 ... H03 0..
H03 1..
H03 2..
H03 3..
We declare under our sole responsibility that the product de-
scribed under “Technical data” is in conformity with the following 
standards or standardization documents: EN 60335, EN 13683 ac-
cording to the provisions of the directives 2004/108/EC, 
2006/42/EC, 2000/14/EC.
2000/14/EC: Guaranteed sound power level
Conformity assessment procedure according to Annex V.
dB(A)
92
92
Dr. Egbert Schneider
Senior Vice President
Engineering
Dr. Eckerhard Strötgen
Head of Product
Certification