Kaiser Nienhaus 136050 N/A 136050 Data Sheet
Product codes
136050
140000 - 144000
Tubular motor with integrated reciever
140000 - 144000
Tubular motor with integrated reciever
50
RI
9. SETTING THE END LIMITS - UP
1. Press and hold Prog-FC button of the MASTER transmitter till the motor jogs. It is the motor feedback
indicating that the setting procedure begins.
ATTENTION: Always set the UP LIMIT FIRST! A short stop of the motor’s travel indicates that the
motor is running in the setting procedure.
2. Press the UP button of the transmitter: the motor begins to move towards UP limit.
Then follow one of the 2 options. Remember the motor operates in a momentary fashion:
UP
PROG-FC
1
2
OPTION 1
SHUTTER WITH MECHANICAL STOPS
OR CASSETTE AWNINGS
A. Wait for the motor stops itself because the
shutter/awning has reached its upper reference
point;
B. The end limit is self-set.
OPTION 2
SHUTTER OR AWNINGS
WITHOUT STOPS
A. be prepared to stop the motor at its UP limit;
B. for an accurate setting press again Prog-FC
button when the shutter/awning is close to the
limit, the motor will run slowly towards the
correct UP limit;
C. Stop the motor at the desired UP limit pressing
the STOP button. The motor jogs;
It is the motor feedback indicating that the UP
limit is set.
PROG-FC
STOP
Tubular motors with electronic end limit and
integrated receiver
50
RI
10. SETTING THE END LIMITS - DOWN
1. Once set the UP limit press the DOWN button of the MASTER transmitter, the motor begins to move
towards DOWN limit.
2. Be prepared to stop the motor at its DOWN limit. For an accurate setting press again Prog-FC button
when the shutter/awning is close to the limit, the motor will run slowly towards the correct DOWN limit.
3. Stop the motor at the desired DOWN limit pressing the STOP button. The motor jogs.
It is the motor feedback indicating that the DOWN limit is set and the setting procedure is made.
UP
1
3
2
STOP
PROG-FC
Tubular motors with electronic end limit and
integrated receiver