17. With an adequately sized crane, carefully lower 
the motor onto the motor adapter, lining up the 
electrical conduit connection and the 4 motor 
adapter bolt holes, as required.
18. Install the 4 motor hex cap screws, torquing to the 
value provided in the “ENGINEERING DATA” 
section of this manual.
19. Place the coupling drive pin into the pump shaft 
and install the coupling halves onto the motor and 
pump shafts. Install the 4 coupling socket head 
screws, lock washers and nuts, DO NOT tighten. 
20. Position the motor assembly shim between the 
coupling and the motor adapter. If the motor 
assembly shim is not available, a 0.03" (5 mm) 
shim may be used to locate the pump shaft assem-
bly and to set the correct height.
21. Tighten the 4 coupling socket head screws, 
torquing screws to values provided in the “ENGI-
NEERING DATA” section of this manual. Tighten 
evenly so that the gap between the halves is equal 
side to side and top to bottom.
22. Install the  coupling guard halves.
  
  1. Close all necessary suction and discharge valves to 
isolate the pump from the system.
  2. Drain the liquid from the pump by removing the  
drain plug and opening the needle valve on the 
vent plug.
  3. Remove the coupling guards, the 4 coupling hex 
cap screws, the coupling and coupling drive pin. 
See steps 1-3.   
  4. Remove the 4 motor hex cap screws (inner 
screws) on the seal housing. See step 4.
  5. Remove the seal housing plate using the two 
tapped holes provided. Threading  of the hex 
cap screws into these holes and evenly tighten-
ing the screws. Lift and remove the seal housing 
between the pump and motor shaft. Exercise care 
when sliding the seal housing between the shaft to 
prevent damage to the stationary seat. See step 5.
  6. Turn the seal housing upside down and remove 
the stationary seat and o-ring. Remove and dis-
card the large o-ring used to seal the seal housing 
to the pump head. Inspect the seal seat for any 
burrs or debris. Make sure that the seat is clean. 
Lubricate the new o-ring for the seal seat with a 
adequately sized crane, carefully remove the mo-
tor. DO NOT rest the motor on the motor shaft.
  5. Remove the 4 tie rod nuts and lock washers.
  6. Carefully remove the motor adapter by sliding it 
up the pump shaft.  Larger units may require an 
adequately sized crane to lift the motor adapter. 
DO NOT damage the shaft.
NOTICE:  EDGES OF THE STAINLESS STEEL PARTS 
ARE SHARP. WEAR APPROPRIATE PRO-
TECTIVE CLOTHING.
  7. To gain access to the mechanical seal, it is neces-
sary to remove the stainless steel upper plate 
which is held in place by an O-ring located under 
the plate rim. Place a small block of wood against 
the underside of the rim and, while moving 
around the rim, tap with a mallet against the block 
until the upper plate loosens. Remove the upper 
plate and O-ring from the pump casing. Discard 
the O-ring.      
  8. Remove the stationary element from the upper 
plate. With a clean cloth, wipe the upper plate 
bore clean and inspect for damage. Replace the 
upper plate, as required.
  9. Remove the top (vented) stainless steel inner cas-
ing. Grasp the pump shaft, below the mechanical 
seal, and move it sharply back and forth to free 
the first stage from the lower pump body. Remove 
the entire stack assembly from the pump external 
sleeve.  
10. Slide the mechanical seal rotary element, spring 
and washer from the pump shaft. Discard the 
entire mechanical seal assembly.
11. Lubricate the inside of the new mechanical seal as-
sembly with a quality grade of O-ring lubricant.  
12. To install a new mechanical seal rotary assembly, 
slide the assembly onto the pump shaft, spring end 
first. Be sure the top spring tip is in the hole of the 
rotary portion of the seal. DO NOT scratch or 
otherwise damage the seal face. With a clean, lint 
free cloth, wipe the seal face clean of all lubricant 
or debris.
13. Lubricate the outside of the new mechanical seal 
stationary element with a quality grade of O-ring 
lubricant. 
14. Insert the stationary seat into the seal housing 
with the seal face out. DO NOT scratch or other-
wise damage the seal face. Insure that the station-
ary seat is fully seated into the seal housing. With 
a clean, lint free cloth, wipe the seal face clean of 
all lubricant or debris.
15. With a new O-ring, install the seal housing onto 
the pump shaft, seating the plate fully and square-
ly onto the pump outer shell.
16. Place the motor adapter over the 4 tie rod bolts, 
using an adequately sized crane when required, 
and install the 4 lock washers and tie rod nuts. 
Torque the nuts, in sequence, to the value pro-
vided in the “ENGINEERING DATA” section of 
this manual.
MECHANICAL SEAL OPTIONS
Code
Rotary
Stationary
Elastomers
No.
A
Carbon
Viton
Mechanical
B
EPR
Seal
C
Silicon
Silicon
Viton
D
Carbide
Carbide
EPR
Cartridge
L
Carbide
Viton
Seal
P
Sil/Carbide
Aflas
Metal parts on all seals are 316SS. When reordering units with previous seal op-
tions 2, 3 or 5 review application and order new seal option from above chart.
A