ITT SSV User Manual

Page of 56
9
WARNING
Hazardous voltage
can shock, burn or
cause death.
For the 33 through 9SV sizes using a cartridge seal, 
after coupling bolts have been properly torqued, 
there are four set screws on the collar of the car-
tridge seal that require tightening before removing 
the shim. The four hex head set screws require a 1/8" 
allen wrench and are to be tightened hand-tight ap-
proximately 5 lbs.-ft. (7 N
m).
Remove the motor assembly shim and retain for 
future use.
Install the  coupling guard halves.
  
1. WATER CONNECTION
The water connections must be made by qualified 
installation technicians in compliance with the regu-
lations in force.
In case of connection to the water system, the regu-
lations issued by the competent authorities (mu-
nicipal, public utility company) must be observed. 
Authorities often require the installation of a back-
flow prevention device, such as a disconnector, check 
valve or disconnection tank.
2. WIRING AND GROUNDING
Install, ground and wire accord-
ing to local and  National Elec-
trical Code requirements.
Install an all leg disconnect 
switch near pump.
Disconnect and lockout electri-
cal power before installing or 
servicing pump.
Electrical supply MUST match pump’s name-
plate specifications. Incorrect voltage can cause 
fire, damage motor and voids warranty.
Motors equipped with automatic thermal pro-
tectors open the motor’s electrical circuit when 
an overload exists. This can cause the pump to 
start unexpectedly and without warning.
Use only stranded copper wire to motor and ground. 
Wire size MUST limit the maximum voltage drop to 
10% of the motor nameplate voltage, at the motor 
terminals. Excessive voltage drop will affect perfor-
mance and void motor warranty. The ground wire 
must be at least as large as the wires to the motor. 
Wires should be color coded for ease of mainte-
nance.
Three phase motors require all leg protection with 
properly sized magnetic starters and thermal over-
loads.
PERMANENTLY GROUND THE 
PUMP, MOTOR AND CONTROLS 
PER NEC OR LOCAL CODES 
BEFORE CONNECTING TO 
ELECTRICAL POWER.  FAILURE 
TO DO SO CAN CAUSE SHOCK, 
BURNS OR DEATH.
Connect the electrical leads to the motor, as follows:
WARNING
Hazardous
voltage
Single Phase Motors – Connect the BLACK wire to 
the BLACK motor wire. Connect the WHITE wire 
to the WHITE motor wire. Connect the GREEN 
wire to the GREEN motor wire.
Three Phase Motors – See figure below.
NOTICE: UNIT ROTATION IS DETERMINED WHEN 
VIEWED FROM MOTOR END. SEE PAGE 16 
FOR MOTOR ROTATION DETAIL. INCOR-
RECT ROTATION MAY CAUSE DAMAGE TO 
THE PUMP AND VOIDS WARRANTY.
Check pump rotation by observing the motor fan or 
the coupling THROUGH the coupling guard. DO 
NOT confuse the flow arrows, stamped on the pump 
body, with the rotation arrows on the coupling and 
motor adapter. Three phase motors only – If rotation 
is incorrect, have a qualified electrician interchange 
any two of the three power cable leads.
3. PRIMING/VENTING
For installations with the liquid level above the pump:
Close the discharge valve.
Remove the vent plug.
For models 1SV and SV only, it is necessary to 
fully unscrew the pin located in the drain plug. 
See figure below.
For sizes 33SV-9SV the vent plug is supplied 
with an internal needle valve, so it is not neces-
sary to remove the vent plug. Simply unscrew 
the needle valve half way to open the valve 
to allow air to escape. (For sizes 33SV-9SV, 
if the pump is supplied with a cartridge seal, 
remove the vent plug located on the gland plate 
beneath the coupling.)
Open the suction valve until liquid flows out of 
the vent plug opening.
208-230V 3/60
460V 3/60
4
5
6
1
7
2
8
3
9
L
1
L
2
L
3
4
7
5
8
6
9
1
2
3
L
1
L
2
L
3
G
G
MOTOR LEADS
MOTOR LEADS
PO
W
ER
C
A
BL
E
LE
A
D
S
PO
W
ER
C
A
BL
E
LE
A
D
S
THREE PHASE MOTOR WIRING DIAGRAM
DRAIN PLUG
WITH PIN CLOSED
DRAIN PLUG
WITH PIN OPEN