Bosch Appliances Home Security System D7412G User Manual

Page of 142
D9412G/D7412G | Program Entry Guide | 2.0 9000MAIN
EN | 30
Bosch Security Systems | 1/04 | 47775E
When P## Supervised is set to Yes and
all Printer Event Groups (such as P##
Fire Events
P## Burglar Event, or P##
Usr Chng Evt
) are set to No, the control
panel does not generate Trouble SDI ##
Reports for the printer if the D9131A
becomes disconnected.
P## Scope
Default:
No Printer
Selection:
No Printer, Area, Account, Panel
Wide, Custom
Panel
Wide
Printer prints all designated events that
occur panel-wide. A panel-wide printer
can cross account boundaries.
Account
Printer prints all designated events that
occur within any area with the same
account number in which this printer is
assigned.
Area
Printer prints all designated events that
occur in the area to which this printer
is assigned.
Custom
See the following Programming Tip.
Printer prints all events occurring in
areas programmed Yes for this prompt
regardless of any boundary restrictions.
No Printer
No printer installed at this address. If a
printer is connected, data does not
print.
Press the [SPACE ] bar to scroll through the
selections. Press [ENTER] when the correct selection
appears in the display.
0101
0101
0101
The following prompts are visible ONLY
when you program P## Scope to Custom.
P## A1 [through A8] in Scope
Default:
No
Selection:
Yes or No
Yes
Include Area # Events in the scope of
this printer.
No
Does not include Area # Events in the
scope of this printer.
Only available if 
P## Scope
 is programmed
Custom. This program item determines whether
events occurring in an area prints at this printer.
See the report tables in Section 2.3
Routing
 to identify the events that print.
Events programmed as No in routing still
print at the local printer. Individual events
within the report group cannot be
suppressed for events printed at the local
printer.
P## Fire Events
Default:
See 
Program Record Sheet
Selection:
Yes or No
Yes
All events in this group print at this
printer.
No
No events in this group print at this
printer.
Use this prompt to determine whether these events
print at this printer.
P## Burglar Event
Default:
See 
Program Record Sheet
Selection:
Yes or No
P## Access Event
Default:
See 
Program Record Sheet
Selection:
Yes or No
P## User Event
Default:
See 
Program Record Sheet
Selection:
Yes or No
P## Test Event
Default:
See 
Program Record Sheet
Selection:
Yes or No
P## Diag Event
Default:
See 
Program Record Sheet
Selection:
Yes or No