D9412G/D7412G | Program Entry Guide | 2.0 9000MAIN
EN | 44
Bosch Security Systems | 1/04 | 47775E
A# Area O/C
Default:
Yes
Selection:
Yes or No
Yes
Include the Area # and generate Opening and
Closing Reports for this area when it is armed.
No
Do not include the Area # or generate
Opening and Closing Reports for this area.
Determines if the area number and the account
number are reported upon arming and disarming.
As long as 
Account O/C
 is No, the account number
reports when arming this area individually. If
Account O/C
 is Yes, all areas with the same
account number must also be armed.
An Area Opening Report is generated when each
area is opened (disarmed). An Area Closing Report
is generated when each individual area is closed
(armed).
Do not program this item as Yes if the
control panel reports to an automation
system that cannot interpret multiple Area
Opening/Closing Reports.
A# Disable O/C in Window
Default:
Yes
Selection:
Yes or No
Yes
Do not send Opening and Closing Reports to
the central station if they occur inside an
active window.
If an Opening or Closing Report occurs
outside a window, send it with an early or late
modifier. See Section 5.1.1 Opening and Closing.
The active window must be a Closing
Window for Closing Reports. It must be an
Opening Window for Opening Reports.
No
Send Opening and Closing Reports to the
central station even when they occur inside a
programmed window. If an opening or closing
occurs outside of the appropriate window, it
reports but does NOT have an early or late
modifier.
If you want to monitor all opening and closing
activity, but you also want to use features
provided by Opening and Closing Windows,
program this item No, and program
appropriate O/C Windows.
Determines if opening and closing activity is
reported when it occurs inside an Opening or
Closing Window as programmed in O/C Windows.
Reports are always logged and printed on a local
printer, if installed.
A# Auto Close
Default:
No
Selection:
Yes or No
Yes
The area automatically master arms at the end
of the Close Window.
When the area is armed automatically, a
Closing Report is sent if Area and/or Account
Reports are programmed to do so.
No
Do not automatically arm the area at the end
of the Close Window.
With this program item, the control panel can
automatically master arm the area at the end of the
Closing Window regardless of the previous armed
state.
Regardless of A# Force Arm Max or P##
Bypassable
, an unconditional force arm
occurs resulting in faulted points being left
out of the system until they return to
normal.
A# Fail to Open
Default:
No
Selection:
Yes or No
Yes
Fail to Open Report occurs for this area if the
area was not disarmed when the Opening
Window stop time occurred.
No
Fail to Open Report is not sent for this area.
Use to determine if a Fail to Open Report is sent for
this area. This can determine if a user failed to
disarm the area prior to the Opening Window
expiring. Normal Opening and Closing Reports do
not need to be programmed to use this feature.