D9412G/D7412G | Program Entry Guide | 2.0 9000MAIN
EN | 46
Bosch Security Systems | 1/04 | 47775E
A# Perimeter O/C
Default:
No
Selection:
Yes or No
Yes
This area can send Perimeter Opening and
Closing Reports.
No
This area cannot send Perimeter Opening and
Closing Reports.
This item determines if this area can send Perimeter
Instant and Perimeter Delay Closing Reports and
normal Opening Reports to the central station.
Opening/Closing Windows do not suppress this
event.
Modem format reporting is required. Some
central station automation systems cannot
process these reports.
2.10
Command Center
This programming module contains three
programming categories: Cmd Cntr Assignment,
Area Text, and Custom Function.
2.10.1
Cmd Cntr (Command Center) Assignment
This programming category assigns a command
center to an area and determines if the command
center is supervised. The command centers are
connected to the control panel using a two-wire
serial data interface bus (SDI bus). This bus can
support up to eight supervised command centers,
each with its own unique command center address
(CC) and corresponding DIP switch address settings.
Should the command centers not be supervised, you
can install multiple command centers with the same
DIP switch address setting for up to 32 unsupervised
command centers.
Cmd Center
Default:
1
Selection:
1 to 8
DIP Switch Setting
SDI
CC#
Address
Number
1
2
3
4
5
6
1
1
ON
ON
ON
ON
--
ON
2
2
OFF
ON
ON
ON
--
ON
3
3
ON
OFF
ON
ON
--
ON
4
4
OFF
OFF
ON
ON
--
ON
5
5
ON
ON
OFF
ON
--
ON
6
6
OFF
ON
OFF
ON
--
ON
7
7
ON
OFF
OFF
ON
--
ON
8
8
OFF
OFF
OFF
ON
--
ON
Enter the command center (CC) number for the SDI address you are programming. This number corresponds to
the DIP switch address settings shown.