D9412GV3/D7412GV3 | Program Entry Guide | 2.0  Panel and Area Wide Parameters 
EN | 73 
 
 
Bosch Security Systems, Inc. | 10/11 | F01U170807-02 
 
L## Bypass a Point 
Default: 
Refer to the program record sheet 
Selection:  - or E 
 
Function 
No. 
Function Name 
Alternate 
Keystroke 
25 
Bypass a Point 
[COMMAND][0] 
Bypass points with this authority level. 
L## Unbypass a Point 
Default: 
Refer to the program record sheet 
Selection:  - or E 
 
Function 
No. 
Function Name 
Alternate 
Keystroke 
26 
Unbypass a Point [COMMAND][0][0] 
Unbypass points with this authority level. 
L## Reset Sensors 
Default: 
Refer to the program record sheet 
Selection: 
- or E 
 
Function 
No. 
Function Name 
Alternate 
Keystroke 
27 Reset 
Sensors [COMMAND][4][7] 
Reset sensors with this authority level. 
L## Change Relay 
Default: 
Refer to the program record sheet 
Selection:  - or E 
 
Function 
No. 
Function Name 
Alternate 
Keystroke 
28 Change 
Relays 
[COMMAND][5][4] 
Manually activate or reset a system relay. 
 
Do not use the Change Relays function 
to toggle relays reserved for special 
functions. Special function relays are 
Area and Panel Wide Relay functions as 
well as relays assigned to CC# Enter 
Key Relay?
 
L## Remote Program 
Default: 
Refer to the program record sheet 
Selection:  - or E 
 
Function 
No. 
Function Name 
Alternate 
Keystroke 
29 
Remote 
Programming 
[COMMAND][4][3] 
Start a remote programming software (RPS) session 
when the phone rings at the control panel. 
L## Move to Area 
Default: 
Refer to the program record sheet 
Selection:  - or E 
 
Function 
No. 
Function Name 
Alternate 
Keystroke 
30 
Move to Area 
[COMMAND][5][0] 
Temporarily switch to a different area and perform 
keypad functions related to that area. 
L## Display Rev 
Default: 
Refer to the program record sheet 
Selection:  - or E 
 
Function 
No. 
Function Name 
Alternate 
Keystroke 
32 
Display Software 
Revision 
[COMMAND][5][9] 
Display the control panel model name and software 
revision. For example: 
9412GV3 REV ##.## 
L## Service Walk 
Default: 
Refer to the program record sheet 
Selection:  - or E 
 
Function 
No. 
Function Name 
Alternate 
Keystroke 
33 
Service Walk 
Test 
(Menu function 
only) 
Start a Service Walk Test for all 24-hour Interior or 
Perimeter Controlled points in the control panel. 
Points are not included in this test if: 
  Points are in an area that is already in a Walk 
Test Mode.  
  Points are assigned to an area that is not 
enabled A# Area On.  
  Points are in an area that is Master or Perimeter 
armed. 
When a Service Walk Test is initiated, one person 
can test all the points in the control panel without 
assistance. The following features are provided with 
the Service Test Mode: 
  Display indicates exactly how many points can be 
tested. 
  Battery and bell tests do not occur during this 
Walk Test. 
  The test ends when all points are tested or the 
test times out after 20 min of inactivity.