D9412GV3/D7412GV3 | Program Entry Guide | 2.0 Panel and Area Wide Parameters
EN | 75
Bosch Security Systems, Inc. | 10/11 | F01U170807-02
Custom Functions
L## C Function 128 [through 143]
Default:
Refer to the program record sheet
Selection: - or E
Function
No.
No.
Function Name
Alternate
Keystroke
Keystroke
128 through
143
143
Enable Custom
Function 128
through 143
Function 128
through 143
(Menu function
only)
only)
Execute the desired Custom Function.
Report Levels
Report Levels
L## Force Arm
Default:
Refer to the program record sheet
Selection: - or E
A user with this authority level can Force Arm.
L## Area O/C
Default:
Refer to the program record sheet
Selection:
- or E
Generates Opening and Closing Reports if the area
where this authority level is assigned sends Opening
and Closing Reports.
where this authority level is assigned sends Opening
and Closing Reports.
L## Restricted O/C
Default:
Refer to the program record sheet
Selection: - or E
Generates an Opening Report if a bell is ringing or a
Closing Report when force or bypass arming. The
area where this authority level is assigned must be
programmed for restricted openings and closings
(refer to the A# Restrictd O/C prompt in Section
2.8.4 Open/Close Options on page 43.
Closing Report when force or bypass arming. The
area where this authority level is assigned must be
programmed for restricted openings and closings
(refer to the A# Restrictd O/C prompt in Section
2.8.4 Open/Close Options on page 43.
L## Perimeter O/C
Default:
Refer to the program record sheet
Selection: - or E
Generates Perimeter Opening and Closing Reports if
the area where this authority level is assigned sends
Perimeter Opening and Closing Reports. Refer to the
A# Perimeter O/C prompt on page 47 in Section
2.8.4 Open/Close Options.
the area where this authority level is assigned sends
Perimeter Opening and Closing Reports. Refer to the
A# Perimeter O/C prompt on page 47 in Section
2.8.4 Open/Close Options.
L## Send Duress
Default:
Refer to the program record sheet
Selection: - or E
Generates a Duress Report if the area where this
authority level is assigned sends duress. (Refer to
the A# Duress Enable prompt on page 39 in Section
2.8.4 Open/Close Options.)
authority level is assigned sends duress. (Refer to
the A# Duress Enable prompt on page 39 in Section
2.8.4 Open/Close Options.)
L## Passcode Arm
Default:
Refer to the program record sheet
Selection: - or E
Arm an area by entering a passcode and pressing
[ENTER].
[ENTER].
L## Passcode Disarm
Default:
Refer to the program record sheet
Selection: - or E
Disarm an area by entering a passcode and pressing
[ENTER].
2.10.7 Access Control Levels
[ENTER].
2.10.7 Access Control Levels
L## Security Level
Default:
Refer to the program record sheet
Selection:
M, P, D, or -
M
Users have access rights for this
area when the area is in any armed
state.
area when the area is in any armed
state.
P
Users have access rights for this
area when the area is Perimeter
Armed or Disarmed but not while the
area is Master Armed.
area when the area is Perimeter
Armed or Disarmed but not while the
area is Master Armed.
D
Users have access rights for this
area only while it is disarmed.
area only while it is disarmed.
-
Users do not have access rights to
this area.
this area.
Security Level [TOKEN FUNCTION]
When the user presents a token or card at the
reader, access is granted only when the user has the
authority to enter the area under certain armed
conditions.
When the user presents a token or card at the
reader, access is granted only when the user has the
authority to enter the area under certain armed
conditions.