SimpleTech ZeusIOPS User Manual

Page of 84
28
Zeus
IOPS
 3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1.0
E
LECTRICAL
 S
PECIFICATIONS
P
OWER
 S
UPPLY
The following voltage specification applies to the drive power connector. Connections to the drive 
should be made in a safety extra low voltage (SELV) circuit.
The drive does not use the +5V supply input pins available on a typical 40-Pin SCA-2 connector. 
The drive uses the +12V supply input. The 5V ground pins are connected to the common ground 
plane within the unit. 
Adequate secondary over-current protection must be incorporated in the host system (drive 
enclosure, backplane, etc.). A 10 amp limit is required for safety purposes.
P
OWER
 R
EQUIREMENTS
The Zeus
IOPS
 3.5-inch Fibre Channel SSD requires a 12V +/-10% DC power source. If a power 
failure occurs, the drive design ensures that the data contained in the storage memory is preserved. 
Data loss or corruption does not occur.
Table 5.
Zeus
IOPS
 3.5-Inch SSD Power Requirements
P
OWER
 C
ONSUMPTION
Table 6.
Zeus
IOPS
 Fibre Channel SSD Typical Power Consumption
CAUTION: To avoid damage to the drive, power
supply voltage transients must not exceed 16
volts.
Item
Requirement
Input Voltage
12V +/-10%
Minimum Voltage
10.8
Maximum Voltage
13.2
Activity
Average Current (mA)
Average Power (W)
Startup
1,200
14.4
Idle
450
5.4
Max Read @ 200MB/sec
700
8.4
Max Write @ 100MB/sec
675
8.1
Read, 1 Block Random I/O @ > 50,000
525
6.3
Write, 1 Block Random I/O @ > 18,000
660
7.9