Table A.  Video Coaxial Cable Wiring Distances 
Cable Type* 
Maximum Distance 
RG59/U 
RG6/U 
RG11/U 
750 ft (229 m) 
1,000 ft (305 m) 
1,500 ft (457 m) 
* Minimum cable requirements: 
75 ohms impedance. All-copper center conductor. 
95% braided copper shield. 
Table B.  24 VAC Wiring Distances 
The following are the recommended maximum distances for 24 VAC with a 
10-percent voltage drop. (Ten percent is generally the maximum allowable 
voltage drop for AC-powered devices.) 
Wire Gauge 
20 
18 
16 
14 
12 
10 
30 vA 
94 ft 
(28 m) 
150 ft 
(45 m 
238 ft 
(115 m)
380 ft 
(72 m) 
603 ft 
(183 m)
960 ft 
(292 m) 
75 vA 
37 ft 
(11 m) 
60 ft 
(18 m) 
95 ft 
(29 m) 
152 ft 
(46 m) 
241 ft 
(73 m) 
384 ft 
(117 m) 
NOTE: Input power for the dome is 24 VAC only. Power consumption is 30 vA 
per dome for indoor models and 75 vA for outdoor models. 
Use a 24 VAC transformer with the following minimum vA: 
40 vA per dome 
For indoor models (without heater) 
100 vA per dome 
For outdoor models (with heater) 
Table C.  Switch Settings for SW1 
Control Type 
Switch Setting 
SW1-1 
SW1-2 
SW1-3 
SW1-4 
SW1-5 
SW1-6 
SW1-7 
SW1-8 
Coaxitron
® 
OFF 
OFF 
OFF 
OFF 
OFF 
OFF 
OFF 
OFF** 
P-Type Control 
ON 
OFF 
OFF 
OFF 
OFF 
OFF 
OFF 
OFF** 
D-Type Control 
OFF 
ON 
OFF 
OFF 
OFF 
OFF 
OFF* 
OFF** 
NOTES:  Switches SW 1-3 through SW 1-6 MUST be OFF. 
D-type control is RS-422 that is compatible with Pelco’s CM6700, MPT9500, CM8500, and Genex
® 
controllers or with 
American Dynamics control systems using the AD2083 Translator. 
P-type control is RS-422 that is compatible with Pelco’s CM6700/CM9750/CM9760 and Genex control systems. 
*  OFF- Use with controllers that have more than 32 presets. 
ON- Use with American Dynamics controllers (32 presets). 
**  OFF - Use with all control systems except CM9502 with variable speed keyboards. 
For CM9502 with fixed speed keyboards, set switch OFF. 
ON - Use with CM9502 with variable speed keyboards for smoother joystick control. 
Pelco Installation Manual C2429M (3/01) 